Temperature Controllers

TC4M with 4–20 ma control output

The TC4M build with 4–20 ma control output.

TC4M temperature controller, 72×72mm, K, E, J, S, R, B, N, T thermocouples
TC4M: 72×72mm; K, E, J, S, R, B, N, T thermocouples; Dual output: relay or SSR drive, plus 4–20mA control.
Output
4–20 mA control output
Bezel
72 × 72
Panel cut-out
68 × 68
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesTC4 series — TC4S, TC4H, TC4W, TC4M, TC4L
ModelTC4M, 72×72mm
Supply220VAC, 50/60Hz
Measurement accuracy±0.5%FS or ±1.0%FS
Control methodPID control and ON/OFF (hysteresis) control
Alarm rangefreely settable across the full range
InputK, E, J, S, R, B, N, T thermocouples; Pt100 and Cu50 RTD — ten input types in total
OutputDual output: relay or SSR drive, plus 4–20mA control
Auxiliary outputOptional 4–20 mA retransmission output or RS485 Modbus communication, by order code
Panel size72×72mm
Panel cut-out68×68mm
Depth75mm
Front protectionIP44 front
Range and sensorset at order: the thermocouple or RTD type and the measuring range are fixed when the unit is built, and the front label is printed to match
Response time1s
Operating environment0…50°C, 30–85%RH, no corrosive gas

Product overview

Part no. SE-TC4M

Also known as: Autonics TC4M · TC4M temperature controller · TC4M PID controller · TC4M controlador de temperatura

TC4M is the 72×72mm member of the TC4 series: a dual-row display of measured value and setpoint, dual output that can be relay or SSR drive, and up to two alarm relays. The front is IP44, the case 75mm deep, and the input accepts ten thermocouple and RTD types without a separate ordering code for the sensor. Communication and current transmission are added by code, so one stock unit covers most of a panel.

Ordering code

TC4M Universal, 4–20 mA control output

The TC4M build with 4–20 ma control output.

Order codeTC4M Universal, 4–20 mA control output
Bezel (mm)72 × 72
Cut-out (mm)68 × 68
Output4–20 mA control output
Output terminalsper the case diagram
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: Selected on the order line; the terminals follow the case diagram for that version

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Reading this order code

How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.

PositionReadsMeaning
1TC44-digit dual-row LED family
2M72 × 72mm DIN bezel, 68 × 68mm cut-out
inputUniversalSensor the controller is set up for
option4–20 mA control outputThe version chosen on the order line
Output terminals: per the case diagram·Selected on the order line; the terminals follow the case diagram for that version

Key features

  • 72×72mm front on a 68×68mm cut-out, 75mm depth behind the panel
  • Dual-row display: measured value in red above, setpoint in green below
  • Dual output — relay contact or SSR drive — plus 4–20mA control on the 8 version
  • Up to two alarm relays, full-range setpoint, visible ALM1 / ALM2 indicators
  • Ten input types on one unit: K, E, J, S, R, B, N, T, Pt100 and Cu50
  • PID or ON/OFF (hysteresis) control, with auto-tuning indicated on the panel
  • Optional 4–20mA transmission and RS485 Modbus by the fifth code position
  • IP44 front protection, 0–50°C ambient, no corrosive gas

Works with

The parts that go into the same panel and are usually ordered with it.

Ordering & Selection Guide

The code has five positions: TC4, then the panel size, the output type, the alarm count, the input type, and an optional suffix for current output or RS485. Reading it left to right tells you everything about the unit without a second table.

TC4−MSizeROutput2AlarmsTCInput−RS485Option

1. Panel size

S48×48×75mm, cut-out 45×45
H48×96×75mm, cut-out 45×92
W96×48×75mm, cut-out 92×45
M72×72×75mm, cut-out 68×68
L96×96×75mm, cut-out 92×92

2. Output type

RRelay contact output (RELAY)
QVoltage pulse output (SSR drive)
8Current output 4–20mA (control)

3. Alarms

1One alarm output (ALM1)
2Two alarm outputs (ALM1 and ALM2)

4. Input type

TCThermocouple: K, E, J, S, R, B, N, T
RtRTD: Pt100, Cu50

5. Additional functions

4Current output 4–20mA (transmission)
RS485RS485 communication

Worked example

TC4M-R2TC-RS485

72×72mm panel on a 68×68mm cut-out, relay output, two alarms, thermocouple input, with RS485. The same hardware without the suffix is the plain version; the suffix only ever adds a function.

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

Panel and keys

Two four-digit rows, the measured value above in red and the setpoint below in green, each ending in its own PV or SV mark. The four lamps sit in two columns to the left of the setpoint row — OUT above AT, ALM2 above ALM1. The MODE key is the yellow one; the other three shift, decrease and increase.

Panel marking
PV
Measured value (PV), red row
SV
Setpoint (SV), green row
OUT
Control output indicator (OUT)
AT
Auto-tuning indicator (AT)
ALM1
First alarm indicator (ALM1)
ALM2
Second alarm indicator (ALM2)
MODE
Mode key — opens the parameter list and confirms a value
◁
Shift key — moves between the digits
∨
Decrease key
∧
Increase key

Wiring

Four sheets for the four bodies: the relay version into a contactor, the same version into a solid-state relay, the alarm beacon with the terminal reference beside it, and the RS485 versions in both output versions. The sensor lands on 5, 6 and 7 whichever version you have.

Relay output into a contactor, SSR output into a solid-state relay

Relay output into a contactor, SSR output into a solid-state relay

8 and 9 take the supply, 10 and 11 the output; 9–13 is linked on the contactor sheet. The heater hangs across T1 and T2 on the contactor, or across the SSR's two output terminals.

Alarm beacon on ALM1, with the terminal reference

Alarm beacon on ALM1, with the terminal reference

ALM1 closes 12–13–14 at 250 VAC 5 A; jumper 9–10 feeds the beacon's live. The reference beside the drawing gives the group each terminal belongs to.

RS485 version with SSR output

RS485 version with SSR output

RS485 on 3 (A+) and 4 (B−); on the single-output build the 12 VDC SSR drive leaves on 10 and 11, and ALM1 keeps its own contact group, set out in the terminal reference beside the drawing.

RS485 version with relay output into a contactor

RS485 version with relay output into a contactor

RS485 on 3 and 4, the relay output on 10 and 11 closing the coil, 9–10 linked, heater across T1 and T2.

Download the four sheets (PDF)

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the TC4M need?

72×72mm. The cut-out is 68×68mm

Which sensors can the TC4M read?

K, E, J, S, R, B, N, T thermocouples; Pt100 and Cu50 RTD — ten input types in total

What output options does the TC4M have?

Dual output: relay or SSR drive, plus 4–20mA control

What supply voltage does the TC4M need?

220VAC, 50/60Hz

Does the TC4M have alarm outputs?

freely settable across the full range

What is the temperature range?

set at order: the thermocouple or RTD type and the measuring range are fixed when the unit is built, and the front label is printed to match

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.