TC4S with 30 a relay output

The TC4S build with 30 a relay output.

TC4S temperature controller, 48×48mm (1/16 DIN), K, E, J, S, R, B, N, T thermocouples; Pt100 and Cu50 RTD
TC4S: 48×48mm (1/16 DIN); K, E, J, S, R, B, N, T thermocouples; Pt100 and Cu50 RTD; Control output by ordered version: a relay contact, an SSR drive….
Output
30 A relay output
Bezel
48 × 48
Panel cut-out
45 × 45
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

ModelTC4S, 48×48mm
Supply220VAC, 50/60Hz
Measurement accuracy±0.5%FS or ±1.0%FS
Control methodPID control and ON/OFF (hysteresis) control
Alarm rangefreely settable across the full range
InputK, E, J, S, R, B, N, T thermocouples; Pt100 and Cu50 RTD
OutputControl output by ordered version: a relay contact, an SSR drive, both together on the dual-output build, or a 4–20 mA current output (order code 8)
Panel size48×48mm (1/16 DIN)
Panel cut-out45×45mm
Depth75mm total, 71mm behind the panel
Front protectionIP44 front
Operating environment0…50°C, 30–85%RH, no corrosive gas

Product overview

Part no. SE-TC4S

Also known as: Autonics TC4S · TC4S temperature controller · TC4S PID controller · TC4S controlador de temperatura

TC4S is the 48×48mm (1/16 DIN) member of the TC4 family: a four-digit display of measured value and setpoint, with dual output available as a relay contact or an SSR drive. The input accepts thermocouple and RTD types on one unit, the front is IP44, and the case is 71mm behind the panel line.

Ordering code

TC4S Universal, 30 A relay output

The TC4S build with 30 a relay output.

Order codeTC4S Universal, 30 A relay output
Bezel (mm)48 × 48
Cut-out (mm)45 × 45
Output30 A relay output
Output terminalsper the case diagram
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: Selected on the order line; the terminals follow the case diagram for that version

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Reading this order code

How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.

PositionReadsMeaning
1TC44-digit dual-row LED family
2S48 × 48 mm (1/16 DIN) DIN bezel, 45 × 45mm cut-out
inputUniversalSensor the controller is set up for
option30 A relay outputThe version chosen on the order line
Output terminals: per the case diagram·Selected on the order line; the terminals follow the case diagram for that version

Key features

  • 48×48mm front on a 45×45mm cut-out, 71mm behind the panel
  • Dual-row display: measured value above, setpoint below
  • Relay contact or SSR drive, chosen by the output code
  • Up to two alarm outputs with full-range setpoints
  • Thermocouple and RTD input on one unit
  • PID or ON/OFF (hysteresis) control with auto-tuning
  • Optional Optional 4–20 mA retransmission output or RS485 Modbus communication, by order code, chosen by the fifth code position
  • IP44 front, 0–50°C ambient

Works with

The parts that go into the same panel and are usually ordered with it.

Ordering & Selection Guide

The code has five positions: TC4, then the panel size, the output type, the alarm count, the input type, and an optional suffix for current output or RS485. Reading it left to right tells you everything about the unit without a second table.

TC4−SSizeROutput2AlarmsTCInput−RS485Option

1. Panel size

S48×48×75mm, cut-out 45×45
H48×96×75mm, cut-out 45×92
W96×48×75mm, cut-out 92×45
M72×72×75mm, cut-out 68×68
L96×96×75mm, cut-out 92×92

2. Output type

RRelay contact output (RELAY)
QVoltage pulse output (SSR drive)
8Current output 4–20mA (control)

3. Alarms

1One alarm output (ALM1)
2Two alarm outputs (ALM1 and ALM2)

4. Input type

TCThermocouple: K, E, J, S, R, B, N, T
RtRTD: Pt100, Cu50

5. Additional functions

4Current output 4–20mA (transmission)
RS485RS485 communication

Worked example

TC4S-R1TC

48×48mm panel on a 45×45mm cut-out, relay output, one alarm, thermocouple input, no suffix. Adding 4 gives 4–20mA transmission; adding RS485 gives the talking version.

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

Dimensions

One size only: a 48×48 front on a 45×45 cut-out. The case is 75mm to the back, 71mm of it behind the panel line.

Panel (mm)Cut-out (mm)Total depthBody depth
48 × 4845 × 4575mm71mm

Wiring

The 48 × 48 body, in both electronics: dual output and RS485. Each has a contactor arrangement, an SSR arrangement and — on the dual-output version — an alarm beacon, with the rear terminal order for every block at the foot of the sheet.

TC4S · dual output and RS485 wiring, with terminal diagrams

TC4S · dual output and RS485 wiring, with terminal diagrams

On the dual-output version the relay uses 3 / 4 / 5 with a 2–4 jumper, the SSR drive leaves on 11 (+) and 12 (−), and the beacon hangs on 6 / 7 with a 2–7 jumper. On the RS485 version 11 and 12 become A+ and B−, and the SSR drive moves to 3 (+) and 4 (−). The sensor stays on 9 (−) / 10 (+) with the RTD on 8 / 9 / 10 either way.

Download the sheet (PDF)

Documents for this family

All documents

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the TC4S need?

48×48mm (1/16 DIN). The cut-out is 45×45mm

Which sensors can the TC4S read?

K, E, J, S, R, B, N, T thermocouples; Pt100 and Cu50 RTD

What output options does the TC4S have?

Control output by ordered version: a relay contact, an SSR drive, both together on the dual-output build, or a 4–20 mA current output (order code 8)

What supply voltage does the TC4S need?

220VAC, 50/60Hz

Does the TC4S have alarm outputs?

freely settable across the full range

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.