Temperature Controllers

TEL72-9001T with 40 a relay output

The 40 A build on a 220 V supply.

TEL72-9001T digital and TEL72-8001B pointer temperature controllers side by side
TEL72-9001T on the left, the digital version; TEL72-8001B on the right, the pointer version.
Output
40 A relay output
Bezel
72 × 72
Panel cut-out
68 × 68
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

Product NameDigital Dial Temperature Controller
ModelsTEL72-9001T digital, TEL72-8001B pointer
SeriesTEL72 Series
Control methodON/OFF position control
DisplayThree-digit red LED temperature display with rotary setpoint dial
Input TypeK-type thermocouple
Temperature range0–400°C
Accuracy±1.5%FS setting; ±1.0%FS indication
Resolution1°C
Output TypeRelay output, position control
Alarm outputNone — this model has no alarm relay
Thermocouple typeK as standard; E available, both 0–400°C
Service life10,000 operations or more
Relay contact rating10A relay contact
Load Power500W direct resistive load; use an AC contactor above that limit
Power Supply220VAC, 380VAC 50/60Hz versions
Power consumption≤3VA
Panel size72×72mm
Panel cutout68×68mm
Dimensions (depth)103mm from the front face to the rear on the short case; 110mm on the long case
Weight0.273kg
Gross Weight350g gross packaged weight
CertificationCE
MountingPanel-mounted, snap-in clips
ApplicationOvens, electric griddles and industrial heating equipment

Product overview

Part no. SE-TEL72-9001T

Also known as: TEL72-9001T temperature controller · TEL72-9001T On/Off Temperature Controller · TEL72-9001T controlador de temperatura

The TEL72 series sets its target with a front dial and reads the result either on a red LED display (TEL72-9001T) or against a pointer scale (TEL72-8001B). Its ON/OFF relay control is intended for straightforward oven, griddle and heating-equipment applications. The standard configuration has a K-type input and a single-phase wiring example; other input and supply options are available, so specify the exact version when ordering.

Ordering code

TEL72-9001T 40 A 220 V

The 40 A build on a 220 V supply.

Order codeTEL72-9001T 40 A 220 V
Bezel (mm)72 × 72
Cut-out (mm)68 × 68
Output40 A relay output
Output terminalsper the case diagram
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: Switches the oven element directly; the ampere rating is what the oven draws

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Reading this order code

How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.

PositionReadsMeaning
modelTEL72-9001T72 × 72mm oven controller, the 9001T digital or the 8001B pointer dial
current40 ARelay rating, chosen to the oven's draw
supply220 VSupply the panel provides
inputKK thermocouple, the probe these ovens ship with
Output terminals: per the case diagram·Switches the oven element directly; the ampere rating is what the oven draws

Key features

  • Red LED display with rotary dial setpoint
  • ON/OFF position control control for straightforward heating regulation
  • 0–400°C range with K-type thermocouple input as standard
  • Relay output in 10 A, 30 A or 40 A on the digital model
  • Direct resistive load is limited to 500W; use a contactor above that
  • Supply in 220 V, 380 V or a 12 V single supply
  • 72×72mm front, 68×68mm panel cut-out
  • ≤3VA power consumption
  • CE-marked panel-mounted design

Works with

The parts that go into the same panel and are usually ordered with it.

Setpoint, panel fit & ordering checks

The TEL72-9001T pairs a rotary setpoint dial with a red LED measured-temperature display. It is an ON/OFF relay controller for ovens, electric griddles and other straightforward heating applications.

Accuracy is quoted both as separate setting and indication figures and as a single figure. The case comes in two depths — 103mm on the short version and 110mm on the long one — so confirm the input, the supply and which case is on order before cutting the panel.

  • The standard configuration has a K-type input and a 220VAC wiring example; E/K and 220/380V options are also available, so confirm the exact combination.
  • Use an AC contactor above the stated direct-load limit. Do not size a heater from the relay's 10A rating alone.
  • Two case depths: 103mm short, 110mm long. Both take the same 68 × 68mm cut-out, so the depth is the only thing the panel has to clear.
TEL72-9001T outline: 72 × 72 mm front, 68 × 68 mm panel cut-out, and a side view showing the 103 mm short case and the 110 mm long case
Outline: 72 × 72 mm front on a 68 × 68 mm cut-out; the short case runs 103 mm from the front face to the rear and the long case 110 mm.

Build and materials

The instrument is a dial-set controller, so the parts that decide whether it lasts are not on the data plate: the transformer, the relay, the board process, the case and the terminals.

Copper transformer

The supply transformer is wound with copper, which is the part that sets how steady the 220VAC side of the instrument is. It sits on the board stack behind the dial, away from the thermocouple terminals.

10A relay inside the case

The load is switched by a relay block on the board, not by a contact brought out to the terminals. That is what allows the instrument to switch a resistive load up to 500W directly; above that the heater goes through an AC contactor.

Surface-mount board

The control board is machine-placed surface-mount, which is what keeps a 72 × 72mm case with a dial, a display and a 10A relay inside it. The same process is why the calibration does not drift as the unit warms up.

ABS case with cooling slots

The case is ABS, with cooling slots down both sides, and the front carries a clear protective cover over the dial. The front bezel is 72 × 72mm on a 68 × 68mm cutout.

Tinned copper terminals

The six screw terminals are tinned copper, so the screws and the wire ends do not oxidise between commissioning and a service visit years later.

10,000 operations

The supplier quotes a service life of 10,000 operations or more and calls it the single most important technical indicator of a controller. For a two-position controller on a sealing machine that is the number that decides when the unit is replaced, not the accuracy.

Thermocouple type

The model number is the same for both; the thermocouple type is chosen at order and sets the range at 0–400°C either way.

ThermocoupleRangeNotes
K0–400°CStandard build, marked TEL72-9001T on the dial
E0–400°CE thermocouple, same case and range

Where it is used

Four machines account for most of the orders for this model.

Sealing machines

A pedal sealer's bar is a resistive load that is switched on and off all day, which is exactly the duty the 10A relay and the 10,000-operation figure are meant for.

Vacuum packing machines

The sealing bar of a vacuum packer needs a fixed, repeatable temperature; the dial lets the operator set it once and the display shows the actual reading beside it.

Ovens

A small baking or curing oven is the direct-load case: up to 500W the heater runs straight off the relay, and above it the heater goes through a contactor.

Drying cabinets

Drying and incubation cabinets sit at one temperature for days at a time, where a two-position controller is enough and a PID adds nothing an operator can see.

Wiring

Three arrangements, one per load size. The 10 A and 30 A versions switch the heater straight from terminal 6; the 40 A version has its own terminals; above that the output closes a contactor. Terminal 1 takes the thermocouple positive and 2 the negative.

Direct heater connection, 10 A and 30 A versions

Direct heater connection, 10 A and 30 A versions

Supply on 10 and 11, jumper 4–10, output from 6. Direct load limits: 1,500 W on the 10 A version, 4,500 W on the 30 A version. The 380 V version of this controller was marked 9 and 11.

Direct heater connection, 40 A version

Direct heater connection, 40 A version

The 40 A version moves the supply to 3 and 4 with a 4–5 jumper; the load limit is 6,000 W. Check the voltage version of the controller before wiring.

Relay output with an AC contactor

Relay output with an AC contactor

Above the direct limits the output closes a contactor coil on A1, with A2 to neutral; the heater hangs across T1 and T2. The controller's own supply stays on 10 and 11.

Download the three sheets (PDF)

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

Documents for this family

All documents

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the TEL72-9001T need?

72×72mm. The cut-out is 68×68mm

Which sensors can the TEL72-9001T read?

K-type thermocouple

What output options does the TEL72-9001T have?

Relay output, position control

What supply voltage does the TEL72-9001T need?

220VAC, 380VAC 50/60Hz versions

How accurate is the TEL72-9001T?

±1.5%FS setting; ±1.0%FS indication, at 1°C resolution

Does the TEL72-9001T have alarm outputs?

None — this model has no alarm relay