Temperature Controllers
TEL96-2001 with pointer dial
The pointer dial on a 220 / 380 V supply.

- Output
- Pointer dial, 10 A relay output
- Bezel
- 96 × 96
- Panel cut-out
- 92 × 92
Technical specifications
| Models | TEL96-9001 digital, TEL96-2001 pointer |
|---|---|
| Power Supply | 220 VAC on terminals 8–9; 380 VAC on terminals 8–10 (13-terminal block, no terminal 7); optional 12 V single-supply version for machine panels |
| Temperature Range | 0–400°C |
| Digital Display Accuracy | ±1.0% FS |
| Pointer Accuracy | ±2.5% FS |
| Control Method | ON/OFF (position) control with 2°C hysteresis |
| Input Type | K-type thermocouple only — terminal 5 (−), 6 (+) |
| Output Type | Passive (voltage-free) relay contact on terminals 2–3 |
| Relay contact rating | 10A resistive (direct switching up to ~1500 W; above that use an AC contactor) |
| Operating Temperature | 0°C to 50°C |
| Operating Humidity | 30–85% RH |
| Operating Environment | Non-corrosive atmosphere |
| Panel size | 96×96mm (1/4 DIN) |
| Panel cutout | 92×92mm |
| Dimensions (depth) | 100mm body, 110mm with the terminal cover |
| Jumper | Terminal 3 to terminal 9 at 220 VAC, or terminal 3 to terminal 10 at 380 VAC; with it removed the output is open |
Product overview
Part no. SE-TEL96-9001
Also known as: TEL96-9001 temperature controller · TEL96-9001 On/Off Temperature Controller · TEL96-9001 controlador de temperatura
The TEL96-9001 is a reliable, easy-to-operate ON/OFF temperature controller designed for commercial baking ovens, sealing machines, vacuum packaging equipment, and industrial heating tubes. Featuring a clear digital LED readout paired with a front rotary setpoint knob, it eliminates complex menu navigation for machine operators. Built with a K-type thermocouple input, 10A passive relay output, and dual 220 / 380 VAC power wiring, it is also available in the TEL96-2001 analogue pointer version using the exact same 96×96 mm housing.
Ordering code
TEL96-2001 220 / 380 V
The pointer dial on a 220 / 380 V supply.
| Order code | TEL96-2001 220 / 380 V |
|---|---|
| Bezel (mm) | 96 × 96 |
| Cut-out (mm) | 92 × 92 |
| Output | Pointer dial, 10 A relay output |
| Output terminals | per the case diagram |
| Input | Universal, K thermocouple fitted |
| Alarm | Two relays, A to L selectable |
| Supply | 220VAC 50/60Hz, 10VA |
What it can switch: Switches the oven element directly; the 10 A rating is what the element draws
Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.
Other output stages of the same bezel
Reading this order code
How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.
| Position | Reads | Meaning |
|---|---|---|
| model | TEL96-2001 | 96 × 96 mm (1/4 DIN) oven controller: the 9001 digital or the 2001 pointer dial |
| display | Pointer dial | How the setpoint is shown and set |
| supply | 220 / 380 V | Supply the panel provides |
| input | K | K thermocouple, the probe oven builders fit |
Key features
- Simple Dial Setpoint + Digital Readout: Turn the front rotary knob to set temperature (0–400°C) — no parameter menus for oven or machine operators.
- Built-In 10A Passive Relay Output: Directly switches small resistive heaters (up to ~1500 W) or drives an external AC contactor for heavy oven heating banks.
- Dual-Voltage 220 / 380 VAC Power: Standard models support both 220 VAC (terminals 8–9) and 380 VAC (terminals 8–10), plus an optional 12 V version for machine panels.
- Standard 96×96 mm (1/4 DIN) Housing: Fits a 92×92 mm panel cutout; drop-in compatible with the TEL96-2001 pointer-display model.
Works with
The parts that go into the same panel and are usually ordered with it.
Product Details, Dimensions & Wiring
The setpoint is set on the rotary dial and the digital row shows the measured temperature. The case is 96 × 96 mm on the front, fits a 92 × 92 mm cut-out, and measures 100 mm behind the panel — 110 mm once the terminal cover is fitted.
Wiring
Two connections for this instrument: one switching an AC contactor, one driving an ignition controller with its blower and solenoid valve. 8 takes neutral and 9 takes live, 3 is linked to 9 so the output contact switches live out of 2, and the thermocouple lands on 5 and 6.
Relay output with an AC contactor

A2 is fed from the output contact on 2, A1 sits on neutral; the heater hangs across T1 and T2, with live on L1 and neutral on L2.
Ignition controller with blower and solenoid valve

The ignition controller's high-voltage and feedback leads go to the burner, its earth to the panel earth, and the blower and solenoid valve switch from the same output.
AC 380 V power supply: connect the AC 380 V supply to terminals 8 and 10 instead of 8 and 9. Move all wires from terminal 9 to terminal 10 (including the jumper from terminal 3 to terminal 10). Keep all other wiring unchanged. (Ensure the AC contactor coil voltage matches the control circuit voltage.) Terminals 11-14 are spare. Download both sheets (PDF)
One page per order code
Every code this family ships, with the bezel, the output stage and the terminals that output uses.
TEL96-9001
96 × 96mm (1/4 DIN) · cut-out 92 × 92mm
- 13-terminal block — there is no terminal 7
- 2–3 OUT — passive (voltage-free) relay contact rated 10A resistive; jumper terminal 3 to 9 at 220 VAC, or 3 to 10 at 380 VAC, to switch live out of terminal 2
- 5–6 — K-type thermocouple input, − on 5 and + on 6 (supplied GB-standard probes: blue −, red +; always verify polarity on IEC or ANSI probes)
- 8–9 — connect the 220 VAC supply across terminals 8 and 9
- 8–10 — for a 380 VAC supply, connect power to 8 and 10 and move all wires from terminal 9 to terminal 10 (including the jumper from terminal 3); leave other wiring unchanged and match the contactor coil to 380 VAC
- 1, 4 and 11–14 are unused / spare terminals


Documents for this family
- TEL96-2001 / 9001 wiring546 KB · 2026-11-18
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 3 years
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Frequently asked questions
What is the difference between TEL96-9001 and TEL96-2001?
Both share the same 96×96 mm front bezel (92×92 mm cutout), rotary dial setpoint, K-type input, and 10A relay output. TEL96-9001 features a digital LED display (±1.0% FS accuracy), while TEL96-2001 uses an analogue moving-coil pointer scale (±2.5% FS).
Can the TEL96-9001 drive a heater directly, or do I need an AC contactor?
The internal 10A passive relay can switch small single-phase resistive heaters up to ~1500 W directly. For commercial ovens, higher-wattage heating tubes, or 3-phase loads, always use the relay output to drive an external AC contactor to prevent contact welding.
Is TEL96-9001 a PID controller?
No. It is a simple ON/OFF (position) controller with 2°C hysteresis, built for ovens and sealing machines where fast dial adjustment is preferred. If you need auto-tuning PID control or SSR / 4–20 mA output, see our TC4 Series or REX-C900 (96×96 mm) PID controllers.
Related guides
TEL96-9001 or TEL96-2001: Choosing the Right Oven Temperature Controller
The TEL96 series is a 96 x 96 mm on/off oven temperature controller built around a K-type thermocouple input and a 10 A relay contact. It is made in two versions, the TEL96-9001…
Read guide Technical Guides · 2026-08-25TEL96-9001 Temperature Controller Wiring Guide: Direct Heater and AC Contactor Methods
Terminal-by-terminal wiring for the TEL96-9001 ON/OFF temperature controller: K-type thermocouple connection, direct heater switching up to 1500 W, AC contactor control, 220 VAC…
Read guide Technical Guides · 2026-08-23How to Wire REX-C100, REX-C700 and REX-C400/C900 Temperature Controllers
English wiring diagrams for REX-series temperature controllers, including relay, AC contactor, SSR, K-type thermocouple and 3-wire PT100 connections.
Read guideRelated models
All Temperature Controllers
TEL72-9001T Digital Dial Temperature Controller
SE-TEL72-9001T
72×72mm · 68×68mm · 103mm from the front face to the rear on the short case; 110mm on the long case
View details
TCR Digital Dial Temperature Controller — TCR-M, 0–400°C, 100–240 VAC
SE-TCR
TCR Series Digital Dial Temperature Controller is a cost-effective temperature controller designed for simple and reliable heating control…
View details
TC7-D / TC7-R Dial Temperature Controller — thumbwheel or knob, 0–400°C
SE-TC7-D
75mm behind the bezel
View details
BT-72/96 BD & VD Dial Temperature Controller — thumbwheel or dial, 0–400°C
SE-BD-VD
108mm on the 72×72 and 125mm on the 96×96, behind the bezel
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.