Temperature Controllers

TEL96-2001 with pointer dial

The pointer dial on a 220 / 380 V supply.

TEL96-2001 pointer and TEL96-9001 digital oven temperature controllers side by side
TEL96-2001 on the left, the pointer version; TEL96-9001 on the right, the same body with a digital display.
Output
Pointer dial, 10 A relay output
Bezel
96 × 96
Panel cut-out
92 × 92
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

ModelsTEL96-9001 digital, TEL96-2001 pointer
Power Supply220 VAC on terminals 8–9; 380 VAC on terminals 8–10 (13-terminal block, no terminal 7); optional 12 V single-supply version for machine panels
Temperature Range0–400°C
Digital Display Accuracy±1.0% FS
Pointer Accuracy±2.5% FS
Control MethodON/OFF (position) control with 2°C hysteresis
Input TypeK-type thermocouple only — terminal 5 (−), 6 (+)
Output TypePassive (voltage-free) relay contact on terminals 2–3
Relay contact rating10A resistive (direct switching up to ~1500 W; above that use an AC contactor)
Operating Temperature0°C to 50°C
Operating Humidity30–85% RH
Operating EnvironmentNon-corrosive atmosphere
Panel size96×96mm (1/4 DIN)
Panel cutout92×92mm
Dimensions (depth)100mm body, 110mm with the terminal cover
JumperTerminal 3 to terminal 9 at 220 VAC, or terminal 3 to terminal 10 at 380 VAC; with it removed the output is open

Product overview

Part no. SE-TEL96-9001

Also known as: TEL96-9001 temperature controller · TEL96-9001 On/Off Temperature Controller · TEL96-9001 controlador de temperatura

The TEL96-9001 is a reliable, easy-to-operate ON/OFF temperature controller designed for commercial baking ovens, sealing machines, vacuum packaging equipment, and industrial heating tubes. Featuring a clear digital LED readout paired with a front rotary setpoint knob, it eliminates complex menu navigation for machine operators. Built with a K-type thermocouple input, 10A passive relay output, and dual 220 / 380 VAC power wiring, it is also available in the TEL96-2001 analogue pointer version using the exact same 96×96 mm housing.

Ordering code

TEL96-2001 220 / 380 V

The pointer dial on a 220 / 380 V supply.

Order codeTEL96-2001 220 / 380 V
Bezel (mm)96 × 96
Cut-out (mm)92 × 92
OutputPointer dial, 10 A relay output
Output terminalsper the case diagram
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: Switches the oven element directly; the 10 A rating is what the element draws

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Reading this order code

How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.

PositionReadsMeaning
modelTEL96-200196 × 96 mm (1/4 DIN) oven controller: the 9001 digital or the 2001 pointer dial
displayPointer dialHow the setpoint is shown and set
supply220 / 380 VSupply the panel provides
inputKK thermocouple, the probe oven builders fit
Output terminals: per the case diagram·Switches the oven element directly; the 10 A rating is what the element draws

Key features

  • Simple Dial Setpoint + Digital Readout: Turn the front rotary knob to set temperature (0–400°C) — no parameter menus for oven or machine operators.
  • Built-In 10A Passive Relay Output: Directly switches small resistive heaters (up to ~1500 W) or drives an external AC contactor for heavy oven heating banks.
  • Dual-Voltage 220 / 380 VAC Power: Standard models support both 220 VAC (terminals 8–9) and 380 VAC (terminals 8–10), plus an optional 12 V version for machine panels.
  • Standard 96×96 mm (1/4 DIN) Housing: Fits a 92×92 mm panel cutout; drop-in compatible with the TEL96-2001 pointer-display model.

Works with

The parts that go into the same panel and are usually ordered with it.

Product Details, Dimensions & Wiring

The setpoint is set on the rotary dial and the digital row shows the measured temperature. The case is 96 × 96 mm on the front, fits a 92 × 92 mm cut-out, and measures 100 mm behind the panel — 110 mm once the terminal cover is fitted.

Wiring

Two connections for this instrument: one switching an AC contactor, one driving an ignition controller with its blower and solenoid valve. 8 takes neutral and 9 takes live, 3 is linked to 9 so the output contact switches live out of 2, and the thermocouple lands on 5 and 6.

Relay output with an AC contactor

Relay output with an AC contactor

A2 is fed from the output contact on 2, A1 sits on neutral; the heater hangs across T1 and T2, with live on L1 and neutral on L2.

Ignition controller with blower and solenoid valve

Ignition controller with blower and solenoid valve

The ignition controller's high-voltage and feedback leads go to the burner, its earth to the panel earth, and the blower and solenoid valve switch from the same output.

AC 380 V power supply: connect the AC 380 V supply to terminals 8 and 10 instead of 8 and 9. Move all wires from terminal 9 to terminal 10 (including the jumper from terminal 3 to terminal 10). Keep all other wiring unchanged. (Ensure the AC contactor coil voltage matches the control circuit voltage.) Terminals 11-14 are spare. Download both sheets (PDF)

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

TEL96-9001

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

TEL96-2001

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

  • 13-terminal block — there is no terminal 7
  • 2–3 OUT — passive (voltage-free) relay contact rated 10A resistive; jumper terminal 3 to 9 at 220 VAC, or 3 to 10 at 380 VAC, to switch live out of terminal 2
  • 5–6 — K-type thermocouple input, − on 5 and + on 6 (supplied GB-standard probes: blue −, red +; always verify polarity on IEC or ANSI probes)
  • 8–9 — connect the 220 VAC supply across terminals 8 and 9
  • 8–10 — for a 380 VAC supply, connect power to 8 and 10 and move all wires from terminal 9 to terminal 10 (including the jumper from terminal 3); leave other wiring unchanged and match the contactor coil to 380 VAC
  • 1, 4 and 11–14 are unused / spare terminals
TEL96-9001 front and rear views with the 96 mm bezel, 92 mm body and panel cut-out dimensions
Front and rear views: 96 × 96 mm bezel, 92 × 92 mm body — the same 92 × 92 mm the panel is cut to. The body is 100 mm deep, or 110 mm once the terminal cover is fitted.
TEL96-9001 terminal layout and wiring notes for a 13-terminal block with no terminal 7
Terminal layout: passive relay contact on 2–3, K-type thermocouple on 5–6 (− on 5, + on 6), jumper 3–9 at 220 VAC or 3–10 at 380 VAC, and supply across 8–9 at 220 VAC or 8–10 at 380 VAC. Terminals 1, 4 and 11–14 are unused.

Documents for this family

All documents

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What is the difference between TEL96-9001 and TEL96-2001?

Both share the same 96×96 mm front bezel (92×92 mm cutout), rotary dial setpoint, K-type input, and 10A relay output. TEL96-9001 features a digital LED display (±1.0% FS accuracy), while TEL96-2001 uses an analogue moving-coil pointer scale (±2.5% FS).

Can the TEL96-9001 drive a heater directly, or do I need an AC contactor?

The internal 10A passive relay can switch small single-phase resistive heaters up to ~1500 W directly. For commercial ovens, higher-wattage heating tubes, or 3-phase loads, always use the relay output to drive an external AC contactor to prevent contact welding.

Is TEL96-9001 a PID controller?

No. It is a simple ON/OFF (position) controller with 2°C hysteresis, built for ovens and sealing machines where fast dial adjustment is preferred. If you need auto-tuning PID control or SSR / 4–20 mA output, see our TC4 Series or REX-C900 (96×96 mm) PID controllers.

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.