Insulation Monitors
UBCW2K High-Voltage DC Insulation Monitor
High-voltage DC insulation monitor for traction batteries, photovoltaic arrays and DC plant above a kilovolt, in the wide case with two card figures lower.

- System voltage measured
- 0–2000 VDC measured
- Measurement accuracy
- ±2 V from 0 to 400 VDC, ±0.5 % from 400 to 2000 VDC
- Auxiliary supply
- 10–30 VDC, drawing 90 mA at 12 V or 45 mA at 24 V, ≤1.5 W
- Insulation resistance range
- 0 kΩ to 10 MΩ across a 100–2000 VDC system
Technical specifications
| Product | DC insulation monitor for unearthed systems |
|---|---|
| System voltage measured | 0–2000 VDC measured |
| Measurement accuracy | ±2 V from 0 to 400 VDC, ±0.5 % from 400 to 2000 VDC |
| Auxiliary supply | 10–30 VDC, drawing 90 mA at 12 V or 45 mA at 24 V, ≤1.5 W |
| Insulation resistance range | 0 kΩ to 10 MΩ across a 100–2000 VDC system |
| Insulation accuracy | ≤3 kΩ +10 % from 100 to 300 VDC, ≤3 kΩ +5 % from 300 to 2000 VDC, >10 % where Cy² exceeds 0.3 µF and the resistance is above 1 MΩ |
| Reading refresh | first reading 0.7–2 s after switch-on; 0.5–3 s to follow a change |
| Alarm relay | 250 VAC / 30 VDC switching, 3 A, contact resistance <100 mΩ, insulation 100 MΩ |
| Environment | −40 to 75 °C working, −55 to 90 °C storage, ≤90 %RH, ≤3500 m |
Product overview
Part no. SE-UBCW2K
Also known as: UBCW2K insulation monitor
Built for the high-voltage side: traction batteries, large photovoltaic arrays and DC plant that runs above a kilovolt. The case is the wide one, not the slim one, and two figures on the card are smaller than on the lower-voltage units — which is the thing to notice before specifying it.
Key features
- The face, the setting and the response of this version, listed in its own table
- One version per page, because these differ between them
- Photograph and drawing where the factory has supplied one
Works with
The parts that go into the same panel and are usually ordered with it.
Dimensions

Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All Insulation Monitors
UBC1 DC Insulation Monitor for Charging Posts
SE-UBC1
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View details
UBCS1 DIN-Rail DC Insulation Monitor
SE-UBCS1
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View details
UBCH1 Boxed DC Insulation Monitoring Device
SE-UBCH1
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View details
UBCH2 Dual-Channel DC Insulation Monitoring Device
SE-UBCH2
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.