Temperature Controllers
XMTE-1001, E thermocouple, 0–399 °C, 220 V
The XMTE-1001 build with e thermocouple, 0–399 °c, 220 v.

- Output
- E thermocouple, 0–399 °C, 220 V
- Bezel
- 96 × 96
- Panel cut-out
- 92 × 92
Technical specifications
| Series | XMT-1000, thumbwheel setpoint |
|---|---|
| Models | XMTG-1001, XMTE-1001, XMTD-1001 and XMTA-1001 |
| Panel sizes | 48×48×82, 48×96×107, 72×72×65 and 96×96×73 mm |
| Panel cutouts | 45×45, 45×92, 68×68 and 92×92 mm |
| Supply | 220 VAC 50/60 Hz |
| Accuracy | ±1.0 %FS |
| Range | 0–999 °C across the stocked builds |
| Input | K or E thermocouple |
| Setpoint | three-digit thumbwheel under the display |
| Control method | Two-position (on/off) control with a fixed 2 °C differential |
| Output | Relay output, a dry (voltage-free) contact |
| Contact rating | 250 V 3 A |
| Operating environment | 0–50 °C, 30–85 %RH, no corrosive gas |
| Front protection | IP44 |
| Response time | one second |
| Mounting | Panel mount, snap-in clips |
| Typical use | Ovens, incubators, packaging sealers, small heaters and other single-loop machines |
Product overview
Part no. SE-XMT-1000
Also known as: XMT-1000 temperature controller · XMT-1000 On/Off temperature controller
The measured value on the display, the setpoint on a three-digit thumbwheel switch underneath. No menu, no key sequence: whoever is standing at the machine adjusts the thumbwheel and the heat changes. Four bezels, with the output options and contact rating of each build given on its sheet.
Ordering code
XMTE-1001, E thermocouple, 0–399 °C, 220 V
The XMTE-1001 build with e thermocouple, 0–399 °c, 220 v.
| Order code | XMTE-1001, E thermocouple, 0–399 °C, 220 V |
|---|---|
| Bezel (mm) | 96 × 96 |
| Cut-out (mm) | 92 × 92 |
| Output | E thermocouple, 0–399 °C, 220 V |
| Output terminals | per the case diagram |
| Input | Universal, K thermocouple fitted |
| Alarm | Two relays, A to L selectable |
| Supply | 220VAC 50/60Hz, 10VA |
What it can switch: Selected on the order line; the terminals follow the case diagram for that version
Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.
Other output stages of the same bezel
Key features
- XMTG-1001, XMTE-1001, XMTD-1001 and XMTA-1001
- Panels 48×48×82, 48×96×107, 72×72×65 and 96×96×73 mm, cut-outs 45×45, 45×92, 68×68 and 92×92 mm
- K or E thermocouple input, 0–999 °C across the stocked builds
- ±1.0 %FS accuracy, 220 VAC 50/60 Hz supply
- Relay output, dry contact rated 250 V 3 A
Works with
The parts that go into the same panel and are usually ordered with it.
Four bezels
The 1000 series is the thumbwheel-set half of the XMT family: the measured value is on the display and the setpoint is on the three-digit wheel under it, so nobody has to walk a menu to change the heat.
| Model | Panel (mm) | Cutout (mm) |
|---|---|---|
| XMTG-1001 | 48 × 48 × 82 | 45 × 45 |
| XMTE-1001 | 48 × 96 × 107 | 45 × 92 |
| XMTD-1001 | 72 × 72 × 65 | 68 × 68 |
| XMTA-1001 | 96 × 96 × 73 | 92 × 92 |
Ordering & Selection Guide
XMT, the bezel letter, a dash, the series figure 1, then the control mode, the alarm count and the input. The 1 is fixed and carries no position number.
① · Panel size
| G | 48×48×82, cut-out 45×45 |
| E | 48×96×107, cut-out 45×92 |
| D | 72×72×65, cut-out 68×68 |
| A | 96×96×73, cut-out 92×92 |
② · Control mode
| 0 | Two-position control (on/off) |
| 2 | Three-position control |
| 3 | Time-proportioning control |
③ · Alarm output
| 0 | No alarm output |
| 1 | One alarm relay (ALM1) |
| 2 | Two alarm relays (ALM1 and ALM2) |
④ · Input type
| 1 | Thermocouple — K or E |
| 2 | RTD — Pt100 or Cu50 |
Worked example
XMTA-1011
A 96 square unit with two-position control, one alarm relay and a thermocouple input. Change the third digit to a 2 and it takes an RTD; a 3 in the control position selects time proportioning.
How it differs from the 2000 series
Same wheel, same front layout, different case depths and a different code: the 2000 series reads XMT D - 2 ..., this one reads XMT D - 1 .... Both take the same lead colours and the same 250 V 3 A contact, so a panel does not care which is fitted.
Input codes and measuring ranges
Most orders use K02 (K 0–400 °C), K06 (K 0–1200 °C), D10 (Pt100 0–500 °C) or 801 (4–20 mA). Expand the full table below for all 14 sensor types and range codes.
③ Full input code table (14 sensor types: K, J, R, S, B, E, N, T, Pt100, Cu50 & 4–20 mA)
| Input | Code and measuring range |
|---|---|
| KThermocouple | K01 0–200 °CK02 0–400 °CK03 0–600 °CK04 0–800 °CK05 0–1000 °CK06 0–1200 °CK07 0–1372 °CK13 0–100 °CK14 0–300 °C |
| JThermocouple | J01 0–200 °CJ02 0–400 °CJ03 0–600 °CJ04 0–800 °CJ05 0–100 °CJ06 0–1200 °C |
| RThermocouple (accuracy not guaranteed over 0–399 °C) | R01 0–1600 °CR02 0–1769 °CR03 0–1350 °C |
| SThermocouple (accuracy not guaranteed over 0–399 °C) | S01 0–1600 °CS02 0–1769 °C |
| BThermocouple (accuracy not guaranteed over 0–399 °C) | B01 400–1800 °CB02 0–1769 °C |
| EThermocouple | E01 0–800 °CE02 0–1000 °C |
| NThermocouple | N01 1–1300 °CN02 0–1300 °C |
| TThermocouple (accuracy held from −199 to 100 °C) | T01 −199.9–400.0 °CT02 −199.9–100.0 °CT03 −199.9–200.0 °CT04 0–350.0 °C |
| PT100RTD | D01 −199.9–649.0 °CD02 −199.9–200.0 °CD03 −100–50 °CD04 −100–100 °CD05 −100–200 °CD06 0.0–50.0 °CD07 0.0–100 °CD08 0.0–200 °CD09 0.0–300 °CD10 0.0–500 °C |
| Cu50RTD | P01 −50.0–150.0 °CP02 0.0–150.0 °CP03 0.0–100.0 °CP04 −50.0–0.0 °CP05 −50.0–100.0 °CP06 −50.0–50.0 °CP07 −50–150 °CP08 0–150 °CP09 0–100 °CP10 0–50 °C |
| 0–5VDCStandard signal | 401 0.0–100.0 |
| 1–5VDCStandard signal | 601 0.0–100.0 |
| 0–20mAStandard signal, 250 Ω resistor across the terminals | 701 0.0–100.0 |
| 4–20mAStandard signal, 250 Ω resistor across the terminals | 801 0.0–100.0 |
Linear inputs scale over 0.0–100.0 in engineering units; 0–20 mA and 4–20 mA require a 250 Ω shunt resistor across the terminals.
Alarm type codes
The alarm position in the model code is a letter, not a number. These are the twelve codes the REX, CH and XMT families accept, in the order the factory sheets print them, so a code read off one sheet means the same thing on the next.
| Code | Alarm type |
|---|---|
| N | No alarm |
| A | Deviation high (upper) |
| B | Deviation low (lower) |
| C | Deviation high and low |
| D | Band (deviation range) |
| E | Deviation high, hold action |
| F | Deviation low, hold action |
| G | Deviation high and low, hold action |
| H | Process high (absolute) |
| J | Process low (absolute) |
| K | Process high, hold action |
| L | Process low, hold action |
Codes E, F and G behave like A, B and C but stay latched after the condition clears, until the operator resets the instrument. K and L do the same for the absolute limits.
Codes H, J, K and L compare against an absolute temperature instead of an offset from the set point.
One page per order code
Every code this family ships, with the bezel, the output stage and the terminals that output uses.
XMTG-1001
96 × 96mm (1/4 DIN) · cut-out 92 × 92mm
XMTE-1001
96 × 96mm (1/4 DIN) · cut-out 92 × 92mm
XMTD-1001
96 × 96mm (1/4 DIN) · cut-out 92 × 92mm
XMTA-1001
96 × 96mm (1/4 DIN) · cut-out 92 × 92mm
Wiring
Two bodies, two terminal layouts, one sheet: the XMTG-1001 with twelve terminals and the XMTE-1001 with eight, each on a contactor with its electrician's diagram beside it. The 220 V and 380 V versions of either are wired the same way — only the transformer inside differs.
XMTG-1001 / XMTE-1001 · wiring and electrician's diagrams
Read the panel for the body you have: the two blocks here are numbered differently, and the jumper moves with them — 2–5 on the XMTG body, 5–8 on the XMTE. Thermocouple polarity follows the block too: red to 12 and blue to 11 on one, red to 1 and blue to 2 on the other.
Documents for this family
- XMT-1000 series wiring207 KB · 2026-11-19
- XMT-6000 (6311 / 6511) wiring325 KB · 2026-11-18
- XMT-8000 series wiring308 KB · 2026-11-18
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 3 years
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
TEL96-9001 or TEL96-2001: Choosing the Right Oven Temperature Controller
The TEL96 series is a 96 x 96 mm on/off oven temperature controller built around a K-type thermocouple input and a 10 A relay contact. It is made in two versions, the TEL96-9001…
Read guide Product Updates · 2025-04-11TCN4 Series PID Temperature Controller: Model Codes, Inputs, Outputs and Commissioning
A working reference for engineers specifying or commissioning a TCN4 series digital PID temperature controller: how the four panel sizes differ, which sensor inputs are accepted,…
Read guide Technical Guides · 2026-08-23How to Wire REX-C100, REX-C700 and REX-C400/C900 Temperature Controllers
English wiring diagrams for REX-series temperature controllers, including relay, AC contactor, SSR, K-type thermocouple and 3-wire PT100 connections.
Read guideRelated models
All Temperature Controllers
XMT M / MS Single-Display Controller — 48×48 to 96×96mm
SE-XMT-MS
One big display and three keys. The measurement fills the front, the mode key steps between the alarm limit and the output limit, and a lamp beside…
View details
6311 Series Digital Temperature Controllers (XMTG / XMTE / XMTD / XMTA fronts)
SE-XMT-6311
The XMT-6311 is the four-bezel member of the XMT-6000 family, and the only one here that reaches the large strip format. One body is built as…
View details
8411 Series PID Temperature Controllers (XMTG / XMTE / XMTD / XMTA fronts)
SE-XMT-8411
The 8000 series is the smaller series' body with a wider instrument behind the bezel: one input that takes the whole thermocouple and RTD range, a…
View details
XMTD Series Digital Temperature Controller
SE-XMTD
The XMTD-2001 and XMTD-2201 are 72×72 mm panel-mount On/Off temperature controllers built for straightforward, menu-free operation. Operators set the…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.