AC Contactors
Auxiliary Contacts and Delay Heads
The blocks that turn a contactor into a control device: front and side auxiliary sets, air delay heads, interlock kits and replacement coils.

- Front blocks
- Clip onto the top of the contactor; ten combinations from one NO up to four NO or four NC
- Side block
- Clips at the side of the contactor
- Delay heads
- Air delay heads, making or breaking, with one NO and one NC of their own
- Interlock
- Mechanical interlock kits that pair two contactors for reversing duty
Technical specifications
| Series | Auxiliary contact blocks, air delay heads and coil for the LC2-D frame |
|---|---|
| Front blocks | Clip onto the top of the contactor; ten combinations from one NO up to four NO or four NC |
| Side block | Clips at the side of the contactor |
| Delay heads | Air delay heads, making or breaking, with one NO and one NC of their own |
| Interlock | Mechanical interlock kits that pair two contactors for reversing duty |
| Coils | Replacement coils for the LC2-D frames from 09 to 95 |
| LA1-DN10 | Front block · 1NO |
| LA1-DN01 | Front block · 0NO + 1NC |
| LA1-DN02 | Front block · 0NO + 2NC |
| LA1-DN11 | Front block · 1NO + 1NC |
| LA1-DN20 | Front block · 2NO |
| LA1-DN22 | Front block · 2NO + 2NC |
| LA1-DN40 | Front block · 4NO |
| LA1-DN04 | Front block · 4NC |
| LA1-DN13 | Front block · 1NO + 3NC |
| LA1-DN31 | Front block · 3NO + 1NC |
| LA8-DN11 | Side block · 1NO + 1NC |
| LA2-DT0 | Making time-delay head · 0.1 to 3 s |
| LA2-DT2 | Making time-delay head · 0.1 to 30 s |
| LA2-DT4 | Making time-delay head · 10 to 180 s |
| LA3-DR0 | Breaking time-delay head · 0.1 to 3 s |
| LA3-DR2 | Breaking time-delay head · 0.1 to 30 s |
| LA3-DR4 | Breaking time-delay head · 10 to 180 s |
| LA9-0932 | Mechanical interlock for LC2-D09 to LC2-D32 |
| LA9-4095 | Mechanical interlock for LC2-D40 to LC2-D95 |
| L9F970 | Mechanical interlock for F115 to F150 and F265 to F400 |
| L9FG970 | Mechanical interlock for F185 to F225 |
| L9FL970 | Mechanical interlock for F630 |
| LX1-D2 | Coil for LC2-D09 to LC2-D95, wound 24 to 480 V |
Product overview
Part no. SE-AUXILIARY-CONTACindustry model AUXILIARY-CONTAC
Also known as: Auxiliary Contacts contactor · Auxiliary Contacts AC contactor
Everything that clips onto the contactor: front blocks from one NO up to four NC, a side block where the front is already full, air delay heads that hold the changeover for a set time, and the interlock kits that pair two contactors for reversing duty. The coil fits the same frames from 09 to 95.
Key features
- Front and side auxiliary blocks
- Air delay heads, making or breaking
- Interlock kits and replacement coils
Works with
The parts that go into the same panel and are usually ordered with it.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
Related models
All AC Contactors
LR-D Thermal Overload Relay
SE-LR-D
A contactor switches the motor; the thermal relay is what stops it cooking when the load jams. The LR-D range runs from a tenth of an amp to…
View details
CJX2 AC Contactor
SE-CJX2
A contactor is the mechanical answer to the same job a solid state relay does: switch a heater or a motor from a control signal. CJX2 covers the…
View details
LC2-D AC Contactor
SE-LC2-D
The general-purpose contactor for motor starting and load switching: three or four poles, nine amps in AC-3 at 380–440 volts up to a hundred and…
View details
LC2-Z DC Contactor
SE-LC2-Z
A contactor built for direct current: the arc does not cross zero on a DC circuit, so the chamber and the throw are made for it. Nine to ninety-five…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.