Contactor with an auxiliary set already on board: nine to ninety-five amps, up to 660 V, and the thermal relay plugs straight on underneath.

- Use
- Remote making and breaking, frequent starting, with the LR2-D thermal relay plugging straight on to make a starter
- Standard
- IEC 60947-4-1 and GB 14048.5
- Insulation
- Rated insulation voltage 690 V
- Working voltage
- Up to 660 V, rated current up to 95 A
Technical specifications
| Series | CJX2N AC contactor |
|---|---|
| Use | Remote making and breaking, frequent starting, with the LR2-D thermal relay plugging straight on to make a starter |
| Standard | IEC 60947-4-1 and GB 14048.5 |
| Insulation | Rated insulation voltage 690 V |
| Working voltage | Up to 660 V, rated current up to 95 A |
| Auxiliary | One NO + one NC as standard; AC-15 rating 1.6 A at 200–240 V and 0.95 A at 380–440 V, thermal 16 A |
| Coil | 24, 48, 110, 220/230, 380/400, 420 or 440 V, 50/60 Hz |
| Pick-up and release | Picks up at 85–110 % Us hot, releases at 20–75 % Us cold and 10–75 % Us at −5 °C |
| Life | Electrical 1,000,000 operations in AC-3; mechanical 6,000,000 |
| Mounting | 35 mm rail, 75 mm rail or M4 screw |
| Terminals | Main M3.5 for 1 to 4 mm²; auxiliary and coil M3.5 |
| CJX2N-09 | 11 A at 200–240 V · 9 A at 380–440 V · 7 A at 500–550 V · Ith 20 A · 2.2 / 3 kW/HP at 200–240 V · 4 / 5.5 kW/HP at 380–440 V · 5 / 7 kW/HP at 500–550 V |
| CJX2N-12 | 15 A at 200–240 V · 12 A at 380–440 V · 9 A at 500–550 V · Ith 25 A · 3 / 4 kW/HP at 200–240 V · 5.5 / 7.5 kW/HP at 380–440 V · 7.5 / 10 kW/HP at 500–550 V |
| CJX2N-18 | 22 A at 200–240 V · 18 A at 380–440 V · 12 A at 500–550 V · Ith 32 A · 4 / 5.5 kW/HP at 200–240 V · 7.5 / 10 kW/HP at 380–440 V · 10 / 12 kW/HP at 500–550 V |
| CJX2N-25 | 30 A at 200–240 V · 25 A at 380–440 V · 18 A at 500–550 V · Ith 40 A · 5.5 / 7.5 kW/HP at 200–240 V · 11 / 15 kW/HP at 380–440 V · 15 / 20 kW/HP at 500–550 V |
| CJX2N-32 | 40 A at 200–240 V · 32 A at 380–440 V · 21 A at 500–550 V · Ith 50 A · 7.5 / 10 kW/HP at 200–240 V · 15 / 20 kW/HP at 380–440 V · 18.5 / 25 kW/HP at 500–550 V |
| CJX2N-38 | 45 A at 200–240 V · 38 A at 380–440 V · 21 A at 500–550 V · Ith 50 A · 9 / 12 kW/HP at 200–240 V · 18.5 / 25 kW/HP at 380–440 V · 18.5 / 25 kW/HP at 500–550 V |
| CJX2N-40A | 50 A at 200–240 V · 40 A at 380–440 V · 34 A at 500–550 V · Ith 60 A · 11 / 15 kW/HP at 200–240 V · 18.5 / 25 kW/HP at 380–440 V · 22 / 30 kW/HP at 500–550 V |
| CJX2N-50A | 60 A at 200–240 V · 50 A at 380–440 V · 39 A at 500–550 V · Ith 80 A · 15 / 20 kW/HP at 200–240 V · 22 / 30 kW/HP at 380–440 V · 30 / 40 kW/HP at 500–550 V |
| CJX2N-65A | 75 A at 200–240 V · 65 A at 380–440 V · 42 A at 500–550 V · Ith 80 A · 18.5 / 25 kW/HP at 200–240 V · 30 / 40 kW/HP at 380–440 V · 37 / 50 kW/HP at 500–550 V |
| CJX2N-80 | 90 A at 200–240 V · 80 A at 380–440 V · 49 A at 500–550 V · Ith 110 A · 22 / 30 kW/HP at 200–240 V · 37 / 50 kW/HP at 380–440 V · 45 / 60 kW/HP at 500–550 V |
| CJX2N-95 | 110 A at 200–240 V · 95 A at 380–440 V · 59 A at 500–550 V · Ith 130 A · 25 / 35 kW/HP at 200–240 V · 45 / 60 kW/HP at 380–440 V · 45 / 60 kW/HP at 500–550 V |
Product overview
Part no. SE-CJX2N
Also known as: Chint CJX2N · CJX2N contactor · CJX2N AC contactor
The contactor with the auxiliary set already built in, so a panel that needs one NO and one NC contact does not have to buy the block. Nine to ninety-five amps at 380–440 volts, coil from twenty-four to four hundred and forty, and the LR2-D relay plugs straight on to make a starter.
Key features
- 1NO + 1NC auxiliary on board
- 9 A to 95 A in AC-3
- Coil 24 V to 440 V
Works with
The parts that go into the same panel and are usually ordered with it.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related models
All AC Contactors
CJX2 AC Contactor
SE-CJX2
A contactor is the mechanical answer to the same job a solid state relay does: switch a heater or a motor from a control signal. CJX2 covers the…
View details
CJX2-F Reversing Contactor
SE-CJX2-F
The large F frames built as a reversing pair: two contactors side by side with the interlocking bar across them, so a forward command cannot meet a…
View details
CJX2-F Three Pole Contactor
SE-CJX2-F-2
The large F frame in three poles, for the circuits that carry a whole machine rather than a motor: a hundred and fifteen to three hundred and thirty…
View details
CJX2-F Four Pole Contactor
SE-CJX2-F-3
The same large F frame with four main contacts, for the supplies where the neutral breaks with the phases or where a second load rides on the same…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.