Thermocouples & RTD Sensors

E thermocouple, M6 patch, 3m lead

The 3m lead on an M6 patch.

Ring terminal patch thermocouple with a stainless braided lead and fork terminals
The ring goes under a screw that is already in the machine; the braided lead runs back to the controller.
Output
E thermocouple, M6 patch screw, 3m lead
Bezel
patch
Panel cut-out
M6
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

Product typeSurface-mount patch thermocouple / RTD for measuring the temperature of a flat surface
ElementK or E thermocouple, or Pt100 RTD
Temperature range0–400°C (listing figure; the patch body, not the element, is the limit)
ToleranceClass 1
Response time1s
PatchGrounded, in a stainless steel patch with a through-bore for a screw or clamp
Bore diameter5mm as standard; 4mm and 6mm to order
Lead length1, 1.5, 2, 3, 4 or 5m on both K and E, made to order beyond that
Lead insulationBraided stainless steel over fibreglass
TerminationBare tails as standard; connector to order
MountingScrewed or clamped to the surface through the patch bore, so the junction sits flat against the part being measured
Typical useInjection moulding machines, extruder barrels, hot runners, platens, heated plates and roller surfaces where a probe cannot be inserted
Terminal / wiring diagramTwo-wire for K and E; three-wire for Pt100. Confirm the colour code on the lead before wiring.

Product overview

Part no. SE-TC-RINGindustry model TC-RING

Also known as: Ring Terminal Thermocouple temperature sensor · Ring Terminal Thermocouple probe

A patch thermocouple measures the surface it is screwed to, not the air around it: the junction sits in a stainless steel patch with a 5mm bore, and a screw or clamp holds the patch flat against the part. That is the only way to read a barrel, a platen or a hot-runner block accurately. The element is K or E thermocouple or a Pt100 RTD, tolerance is Class 1, response is 1s, and the lead runs 1, 1.5, 2, 3, 4 or 5m on both K and E, made to order beyond that in stainless braid.

Ordering code

E thermocouple, M6 patch, 3m lead

The 3m lead on an M6 patch.

Order codeE thermocouple, M6 patch, 3m lead
Bezel (mm)patch
Cut-out (mm)M6
OutputE thermocouple, M6 patch screw, 3m lead
Output terminalsfork or pin terminals
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: The screw size is what the block is drilled for; the lead length is the run back to the panel

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Key features

  • Patch junction held flat against the measured surface
  • K or E thermocouple, or Pt100 RTD
  • 5mm bore as standard; 4mm and 6mm to order
  • Class 1 tolerance, 1s response
  • Stainless braided lead in 1, 1.5, 2, 3, 4 or 5m on both K and E, made to order beyond that
  • Range 0–400°C (listing figure; the patch body, not the element, is the limit)
  • For barrels, platens, hot runners, sealing bars and roller surfaces
  • Two-wire for thermocouple, three-wire for Pt100

Works with

The parts that go into the same panel and are usually ordered with it.

Thermocouple index and ranges

Eight letter codes cover almost everything on a panel. The letter is the alloy pair, and the range beside it is what the pair can be trusted to measure — outside that range the millivolt curve stops being usable, whatever the controller claims.

TypeAlloysWorking rangeWhere it is used
KNiCr–NiSi−200…1300 °CThe default. Ovens, extruders, heat presses, kilns below 1200 °C
ENiCr–CuNi−200…800 °CHighest EMF per degree, so the noisiest installations still read
JFe–CuNi−40…750 °COlder plant and reducing atmospheres; iron oxidises if it gets wet
NNiCrSi–NiSi−200…1300 °CWhere K drifts: long holds, cycling furnaces, sulphur-bearing gas
TCu–CuNi−200…350 °CLow temperature and cryogenic work, chillers, food equipment
SPt10Rh–Pt0…1600 °CKilns and glass; needs a thin sheath and clean air
RPt13Rh–Pt0…1600 °CSame duty as S with a higher output; platinum and ceramic firing
BPt30Rh–Pt6Rh600…1700 °CVery high temperature only: glass melt, refractory, 1500 °C and above

Ranges are the industrial working range, not the full IEC 60584 table. Type B has almost no output below 600 °C, which is why it is never specified for a low-temperature job.

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

How to specify

Three choices: element, bore and lead. PT-K-05-200 is a K type element in a patch with a 5 mm bore on a 2 m braided lead.

PTFamily
KElement
05Bore, mm
200Lead, cm

Fixed in this familyChosen when ordering

PositionCodeSelects
FamilyPTPatch sensor
ElementKK type thermocouple
EE type thermocouple
PPt100 RTD
Bore, mm044 mm bore, to order
055 mm bore, standard
066 mm bore, to order
Lead, cm1001 m lead
2002 m lead
3003 m lead
5005 m lead
  • Lead lengths differ by element: K takes 1, 2 or 5 m; E takes 1 or 2 m; Pt100 takes 1, 2 or 3 m. The code carries the ones we stock.

Dimensions

Two dimensions decide whether the patch fits: the bore, which has to clear the screw or clamp you already use, and the lead. The patch body itself is a fixed size.

Ø5 mm bore (4 / 6 mm to order)Lead 1–5 m

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

Why not just clamp an ordinary probe to the surface?

Because an ordinary probe clamped to a surface is mostly measuring the air around it. The patch puts the junction inside a metal body that is pressed flat against the part, so heat reaches it by conduction through the patch rather than by convection from the surrounding air.

Which bore should I order?

5 mm is standard, and 4 mm and 6 mm are made to order. Pick the bore to suit the screw or clamp you already use — the patch is held by that fixing, so the bore is what decides whether it sits flat.

How fast does it respond?

About a second, which is fast for a surface sensor because the junction is only separated from the part by the thickness of the patch. Response slows sharply if the patch is not flat against the surface, so tighten the fixing rather than ordering a different sensor.

Can it go on a curved surface?

The patch is flat, so on a small-diameter barrel it touches along a line rather than over an area, and the reading suffers for it. Tell us the diameter and we will quote a patch formed to match it — a flat patch forced onto a curve lifts at the edges.

Certification and model-specific options

Certification

If CE or RoHS documentation is required, identify the exact model and ask us to confirm which current documents apply with the quotation. ATEX / IECEx zone-rated assemblies are not listed in this range; confirm requirements before specifying.

OEM and private label

Private-label marking or packaging may be available for selected probe models. The marking locations, supported construction and minimum quantity are confirmed against the model and order in the quotation.

What can be changed

Thread, sheath, lead insulation, terminal style and insertion length depend on the probe model and construction. Send the drawing or installation dimensions and we will confirm available options and quote accordingly.

Tolerance has to be stated

A tolerance class is not implied by a part number. Say Class 1 or Class 2 for K and E type (IEC 60584), Class A or B for Pt100 (IEC 60751), on the order — otherwise the probe is built to the standard class and the loop may not hold the accuracy you designed for.

Pressure

None of these probes is rated for pressure service. If the sensor goes into a pressurised pipe or vessel, ask for a thermowell and we will supply a probe that fits it — a bare sheath in a pressurised line is a leak waiting to happen.

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.