Thermocouples & RTD Sensors
K thermocouple, M6 patch, 4m lead
The 4m lead on an M6 patch.

- Output
- K thermocouple, M6 patch screw, 4m lead
- Bezel
- patch
- Panel cut-out
- M6
Technical specifications
| Product type | Surface-mount patch thermocouple / RTD for measuring the temperature of a flat surface |
|---|---|
| Element | K or E thermocouple, or Pt100 RTD |
| Temperature range | 0–400°C (listing figure; the patch body, not the element, is the limit) |
| Tolerance | Class 1 |
| Response time | 1s |
| Patch | Grounded, in a stainless steel patch with a through-bore for a screw or clamp |
| Bore diameter | 5mm as standard; 4mm and 6mm to order |
| Lead length | 1, 1.5, 2, 3, 4 or 5m on both K and E, made to order beyond that |
| Lead insulation | Braided stainless steel over fibreglass |
| Termination | Bare tails as standard; connector to order |
| Mounting | Screwed or clamped to the surface through the patch bore, so the junction sits flat against the part being measured |
| Typical use | Injection moulding machines, extruder barrels, hot runners, platens, heated plates and roller surfaces where a probe cannot be inserted |
| Terminal / wiring diagram | Two-wire for K and E; three-wire for Pt100. Confirm the colour code on the lead before wiring. |
Product overview
Part no. SE-TC-RINGindustry model TC-RING
Also known as: Ring Terminal Thermocouple temperature sensor · Ring Terminal Thermocouple probe
A patch thermocouple measures the surface it is screwed to, not the air around it: the junction sits in a stainless steel patch with a 5mm bore, and a screw or clamp holds the patch flat against the part. That is the only way to read a barrel, a platen or a hot-runner block accurately. The element is K or E thermocouple or a Pt100 RTD, tolerance is Class 1, response is 1s, and the lead runs 1, 1.5, 2, 3, 4 or 5m on both K and E, made to order beyond that in stainless braid.
Ordering code
K thermocouple, M6 patch, 4m lead
The 4m lead on an M6 patch.
| Order code | K thermocouple, M6 patch, 4m lead |
|---|---|
| Bezel (mm) | patch |
| Cut-out (mm) | M6 |
| Output | K thermocouple, M6 patch screw, 4m lead |
| Output terminals | fork or pin terminals |
| Input | Universal, K thermocouple fitted |
| Alarm | Two relays, A to L selectable |
| Supply | 220VAC 50/60Hz, 10VA |
What it can switch: The screw size is what the block is drilled for; the lead length is the run back to the panel
Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.
Other output stages of the same bezel
Key features
- Patch junction held flat against the measured surface
- K or E thermocouple, or Pt100 RTD
- 5mm bore as standard; 4mm and 6mm to order
- Class 1 tolerance, 1s response
- Stainless braided lead in 1, 1.5, 2, 3, 4 or 5m on both K and E, made to order beyond that
- Range 0–400°C (listing figure; the patch body, not the element, is the limit)
- For barrels, platens, hot runners, sealing bars and roller surfaces
- Two-wire for thermocouple, three-wire for Pt100
Works with
The parts that go into the same panel and are usually ordered with it.
Thermocouple index and ranges
Eight letter codes cover almost everything on a panel. The letter is the alloy pair, and the range beside it is what the pair can be trusted to measure — outside that range the millivolt curve stops being usable, whatever the controller claims.
| Type | Alloys | Working range | Where it is used |
|---|---|---|---|
| K | NiCr–NiSi | −200…1300 °C | The default. Ovens, extruders, heat presses, kilns below 1200 °C |
| E | NiCr–CuNi | −200…800 °C | Highest EMF per degree, so the noisiest installations still read |
| J | Fe–CuNi | −40…750 °C | Older plant and reducing atmospheres; iron oxidises if it gets wet |
| N | NiCrSi–NiSi | −200…1300 °C | Where K drifts: long holds, cycling furnaces, sulphur-bearing gas |
| T | Cu–CuNi | −200…350 °C | Low temperature and cryogenic work, chillers, food equipment |
| S | Pt10Rh–Pt | 0…1600 °C | Kilns and glass; needs a thin sheath and clean air |
| R | Pt13Rh–Pt | 0…1600 °C | Same duty as S with a higher output; platinum and ceramic firing |
| B | Pt30Rh–Pt6Rh | 600…1700 °C | Very high temperature only: glass melt, refractory, 1500 °C and above |
Ranges are the industrial working range, not the full IEC 60584 table. Type B has almost no output below 600 °C, which is why it is never specified for a low-temperature job.
One page per order code
Every code this family ships, with the bezel, the output stage and the terminals that output uses.
K
patchmm · cut-out M4mm
- K thermocouple, M4 patch, 1m lead
- K thermocouple, M4 patch, 2m lead
- K thermocouple, M4 patch, 3m lead
- K thermocouple, M4 patch, 4m lead
- K thermocouple, M4 patch, 5m lead
- K thermocouple, M5 patch, 1m lead
- K thermocouple, M5 patch, 2m lead
- K thermocouple, M5 patch, 3m lead
- K thermocouple, M5 patch, 4m lead
- K thermocouple, M5 patch, 5m lead
- K thermocouple, M6 patch, 1m lead
- K thermocouple, M6 patch, 2m lead
- K thermocouple, M6 patch, 3m lead
- K thermocouple, M6 patch, 4m lead
- K thermocouple, M6 patch, 5m lead
E
patchmm · cut-out M4mm
- E thermocouple, M4 patch, 1m lead
- E thermocouple, M4 patch, 2m lead
- E thermocouple, M4 patch, 3m lead
- E thermocouple, M4 patch, 4m lead
- E thermocouple, M4 patch, 5m lead
- E thermocouple, M5 patch, 1m lead
- E thermocouple, M5 patch, 2m lead
- E thermocouple, M5 patch, 3m lead
- E thermocouple, M5 patch, 4m lead
- E thermocouple, M5 patch, 5m lead
- E thermocouple, M6 patch, 1m lead
- E thermocouple, M6 patch, 2m lead
- E thermocouple, M6 patch, 3m lead
- E thermocouple, M6 patch, 4m lead
- E thermocouple, M6 patch, 5m lead
How to specify
Three choices: element, bore and lead. PT-K-05-200 is a K type element in a patch with a 5 mm bore on a 2 m braided lead.
Fixed in this familyChosen when ordering
| Position | Code | Selects |
|---|---|---|
| Family | PT | Patch sensor |
| Element | K | K type thermocouple |
| E | E type thermocouple | |
| P | Pt100 RTD | |
| Bore, mm | 04 | 4 mm bore, to order |
| 05 | 5 mm bore, standard | |
| 06 | 6 mm bore, to order | |
| Lead, cm | 100 | 1 m lead |
| 200 | 2 m lead | |
| 300 | 3 m lead | |
| 500 | 5 m lead |
- Lead lengths differ by element: K takes 1, 2 or 5 m; E takes 1 or 2 m; Pt100 takes 1, 2 or 3 m. The code carries the ones we stock.
Dimensions
Two dimensions decide whether the patch fits: the bore, which has to clear the screw or clamp you already use, and the lead. The patch body itself is a fixed size.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Frequently asked questions
Why not just clamp an ordinary probe to the surface?
Because an ordinary probe clamped to a surface is mostly measuring the air around it. The patch puts the junction inside a metal body that is pressed flat against the part, so heat reaches it by conduction through the patch rather than by convection from the surrounding air.
Which bore should I order?
5 mm is standard, and 4 mm and 6 mm are made to order. Pick the bore to suit the screw or clamp you already use — the patch is held by that fixing, so the bore is what decides whether it sits flat.
How fast does it respond?
About a second, which is fast for a surface sensor because the junction is only separated from the part by the thickness of the patch. Response slows sharply if the patch is not flat against the surface, so tighten the fixing rather than ordering a different sensor.
Can it go on a curved surface?
The patch is flat, so on a small-diameter barrel it touches along a line rather than over an area, and the reading suffers for it. Tell us the diameter and we will quote a patch formed to match it — a flat patch forced onto a curve lifts at the edges.
Certification and model-specific options
Certification
If CE or RoHS documentation is required, identify the exact model and ask us to confirm which current documents apply with the quotation. ATEX / IECEx zone-rated assemblies are not listed in this range; confirm requirements before specifying.
OEM and private label
Private-label marking or packaging may be available for selected probe models. The marking locations, supported construction and minimum quantity are confirmed against the model and order in the quotation.
What can be changed
Thread, sheath, lead insulation, terminal style and insertion length depend on the probe model and construction. Send the drawing or installation dimensions and we will confirm available options and quote accordingly.
Tolerance has to be stated
A tolerance class is not implied by a part number. Say Class 1 or Class 2 for K and E type (IEC 60584), Class A or B for Pt100 (IEC 60751), on the order — otherwise the probe is built to the standard class and the loop may not hold the accuracy you designed for.
Pressure
None of these probes is rated for pressure service. If the sensor goes into a pressurised pipe or vessel, ask for a thermowell and we will supply a probe that fits it — a bare sheath in a pressurised line is a leak waiting to happen.
Related guides
TEL96-9001 Temperature Controller Wiring Guide: Direct Heater and AC Contactor Methods
Terminal-by-terminal wiring for the TEL96-9001 ON/OFF temperature controller: K-type thermocouple connection, direct heater switching up to 1500 W, AC contactor control, 220 VAC…
Read guide Technical Guides · 2026-11-26TEL96-9001 or TEL96-2001: Choosing the Right Oven Temperature Controller
The TEL96 series is a 96 x 96 mm on/off oven temperature controller built around a K-type thermocouple input and a 10 A relay contact. It is made in two versions, the TEL96-9001…
Read guide Technical Guides · 2026-08-23How to Wire REX-C100, REX-C700 and REX-C400/C900 Temperature Controllers
English wiring diagrams for REX-series temperature controllers, including relay, AC contactor, SSR, K-type thermocouple and 3-wire PT100 connections.
Read guideRelated models
All Thermocouples & RTD Sensors
Simple-Type Thermocouple or RTD | 4 × 40mm Probe, Clamp Mount, K / E / Pt100 / Cu50
SE-TC-4X40
The plainest sensor in the range: a 4 × 40 mm stainless probe on a braided lead, clamped against the part instead of screwed into it. Bolt the clamp…
View details
Sheathed Thermocouple or Pt100 RTD | Cast Aluminium Head, G1/2, 6mm Sheath
SE-TC-WRNK236
One mechanical version, two elements. The WRNK-236 takes a K type thermocouple for readings up to 0–800 °C; the WZP-236 takes a Pt100 for the colder…
View details
NTC Thermistor Temperature Sensor Probe | Stainless, Waterproof, Custom Lead
SE-NTC-PROBE
An NTC thermistor reads resistance rather than microvolts, so the same probe that suits a controller also suits a $5 thermostat: the resistance…
View details
K/E Type Probe Thermocouple Temperature Sensor
SE-TC-KE
A Ø5mm probe in a spring housing. The thread section fixes it to a bracket or a tapped hole, and the spring keeps the tip pressed against the part,…
View detailsNeed help selecting the right model?