Insulation Monitors
UBCS1 DIN-Rail DC Insulation Monitor
DIN-rail DC insulation monitor: face, setting and response for this unit alone in the table below, with the cut-out drawing it needs beneath it.

- DC system voltage measured
- 0–1000 VDC
- DC measurement accuracy
- ±2 V from 0 to 400 VDC, ±0.5 % from 400 to 1000 VDC
- Auxiliary supply
- 10–30 VDC; 120 mA at 12 V or 55 mA at 24 V, ≤1.5 W
- Insulation resistance range
- 0 kΩ–10 MΩ across a 100–1000 VDC system
Technical specifications
| Product | DC insulation monitor for unearthed systems |
|---|---|
| DC system voltage measured | 0–1000 VDC |
| DC measurement accuracy | ±2 V from 0 to 400 VDC, ±0.5 % from 400 to 1000 VDC |
| Auxiliary supply | 10–30 VDC; 120 mA at 12 V or 55 mA at 24 V, ≤1.5 W |
| Insulation resistance range | 0 kΩ–10 MΩ across a 100–1000 VDC system |
| Insulation accuracy, Cy² 0–0.8 µF | ≤60 kΩ: ≤3 kΩ · 60 kΩ–1 MΩ: ≤5 % |
| Insulation accuracy, Cy² 0.8–2.5 µF | ≤60 kΩ: ≤6 kΩ · 60 kΩ–1 MΩ: ≤20 % |
| First reading after switch-on | 0.7–1.4 s |
| Reading refresh after a change | 0.7–2.5 s |
| Earth-switch operations | 50 × 10⁵ |
| Alarm relay | 400 VAC / 600 VDC, 4 A, <100 mΩ, 1000 MΩ at 500 VDC |
| Storage / working temperature | −55 to 90 °C / −40 to 75 °C |
Product overview
Part no. SE-UBCS1
Also known as: UBCS1 insulation monitor
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it is the cut-out it needs.
Key features
- The face, the setting and the response of this version, listed in its own table
- One version per page, because these differ between them
- Photograph and drawing where the factory has supplied one
Works with
The parts that go into the same panel and are usually ordered with it.
Dimensions

Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
Related models
All Insulation Monitors
SZDCG-UBCS1-250 DC Insulation Monitor for Battery Systems
SE-UBCS1-250
The battery-system version of the DIN-rail family, for the voltages a stationary battery runs at: same case, same pluggable terminals at the same…
View details
SZDCG-UBCS1-60 DC Insulation Monitor for Control Circuits
SE-UBCS1-60
The control-circuit version: the low voltages a panel's own rail lives at. Same DIN case and the same terminals as the rest of the family, so a panel…
View details
UBC1 DC Insulation Monitor for Charging Posts
SE-UBC1
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View details
UBCH1 Boxed DC Insulation Monitoring Device
SE-UBCH1
One version per page: the face, the setting and the response that belong to this unit alone are listed in the table below, and the drawing under it…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.