Temperature Controllers

XMTE-6311, K thermocouple, relay output

The XMTE-6311 build with k thermocouple, relay output.

XMT-6311 series digital temperature controllers in four bezels
XMTA, XMTD, XMTE and XMTG: the same controller in four bezels.
Output
K thermocouple, relay output
Bezel
72 × 72
Panel cut-out
68 × 68
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesXMT-6000 series panel temperature controller
ModelsXMTG-6311 / XMTE-6311 / XMTD-6311 / XMTA-6311
Panel sizes48×48×65, 48×96×65, 72×72×65 and 96×96×65 mm
Panel cutouts45×45, 45×92, 68×68 and 92×92 mm
Supply220 VAC, 50/60 Hz
Accuracy±1.0% FS
ControlPID with autotuning, and on/off with an adjustable differential
Inputthermocouple (K or E) on the 1 builds, RTD (Pt100 or Cu50) on the 2 builds
Outputrelay contact 250 V AC 3 A, or SSR drive
Alarm rangefull-range setting
Operating environment0–50 °C, 30–85% RH, no corrosive gas

Product overview

Part no. SE-XMT-6311industry model XMT-6311

Also known as: XMT-6311 temperature controller · XMT-6311 digital panel controller

The XMT-6311 is the four-bezel member of the XMT-6000 family, and the only one here that reaches the large strip format. One body is built as XMTG-6311, XMTE-6311, XMTD-6311 or XMTA-6311, whichever bezel the panel takes, with two output versions: a relay that switches the heater itself, or a drive signal for a solid state relay. PID with autotuning, an on/off mode with an adjustable differential, and a full-range alarm setting.

Ordering code

XMTE-6311, K thermocouple, relay output

The XMTE-6311 build with k thermocouple, relay output.

Order codeXMTE-6311, K thermocouple, relay output
Bezel (mm)72 × 72
Cut-out (mm)68 × 68
OutputK thermocouple, relay output
Output terminalsper the case diagram
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: Selected on the order line; the terminals follow the case diagram for that version

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Key features

  • XMTG-6311 / XMTE-6311 / XMTD-6311 / XMTA-6311
  • Panel cutouts 45×45, 45×92, 68×68 and 92×92 mm
  • 220 VAC, 50/60 Hz supply, ±1.0% FS accuracy
  • relay contact 250 V AC 3 A, or SSR drive
  • 0–50 °C, 30–85% RH, no corrosive gas

Works with

The parts that go into the same panel and are usually ordered with it.

Four bezels, one instrument

The letter after XMT is the panel size and nothing else: four bezels, one body, and the same depth behind every one of them.

ModelPanel W×H (mm)Cutout (mm)
XMTA96 × 96 × 65 mm (1/4 DIN front)92 × 92
XMTD72 × 72 × 65 mm68 × 68
XMTE48 × 96 × 65 mm (1/8 DIN front)45 × 92
XMTG48 × 48 × 65 mm (1/16 DIN front)45 × 45

Ordering & Selection Guide

Four positions after XMT: the bezel letter, the main output, the alarm count and the input. The series digit sits in the middle of the number and never changes, so it carries no position.

XMTG①63②1③1④

① · Bezel letter

G48 × 48 × 65, cut-out 45 × 45
E48 × 96 × 65, cut-out 45 × 92
D72 × 72 × 65, cut-out 68 × 68
A96 × 96 × 65, cut-out 92 × 92

② · Main output

3Relay contact output (RELAY)
5Voltage pulse output (SSR)

③ · Alarm output

1One alarm relay
2Two alarm relays

④ · Input type

1Thermocouple — K or E, named on the order line
2RTD — Pt100 or Cu50

Worked example

XMTG-6311

A 48 square controller, relay output, one alarm, thermocouple input. Which thermocouple is named on the order line — K and E share the code — but an RTD version would read XMTG-6312.

What ships in each version

Two output versions cover most of the work: a relay that switches the heater directly, and an SSR drive for a heater that is switched by a solid state relay. Both carry PID with autotuning and an on/off mode with an adjustable differential.

  • Relay output (63xx)250 V 3 A contact, switching the heater directly through a contactor or on small loads on its own
  • SSR drive (65xx)A logic-level signal for an external solid state relay, the version to specify when the load is above the relay rating

Where this sits against the CD and TEL ranges

These are the cheapest of the panel controllers we stock, and the only ones that reach the large strip format. The CD adds a pointer-free dial and a 4–20 mA option; the TEL range is the one with the rotary scale for ovens.

XMT 6311CDTEL
Bezelsfour, 48 to 96 squarefour, 48 to 96 squareone, 96 square
Outputrelay or SSR driverelay, SSR drive or 4–20 mArelay
Settingkeyskeysrotary dial
Best forthe widest size range at the lowest costa plain setpoint with an analog optionovens and griddles with a dial

Input codes and measuring ranges

Most orders use K02 (K 0–400 °C), K06 (K 0–1200 °C), D10 (Pt100 0–500 °C) or 801 (4–20 mA). Expand the full table below for all 14 sensor types and range codes.

③ Full input code table (14 sensor types: K, J, R, S, B, E, N, T, Pt100, Cu50 & 4–20 mA)
InputCode and measuring range
KThermocouple
K01 0–200 °CK02 0–400 °CK03 0–600 °CK04 0–800 °CK05 0–1000 °CK06 0–1200 °CK07 0–1372 °CK13 0–100 °CK14 0–300 °C
JThermocouple
J01 0–200 °CJ02 0–400 °CJ03 0–600 °CJ04 0–800 °CJ05 0–100 °CJ06 0–1200 °C
RThermocouple (accuracy not guaranteed over 0–399 °C)
R01 0–1600 °CR02 0–1769 °CR03 0–1350 °C
SThermocouple (accuracy not guaranteed over 0–399 °C)
S01 0–1600 °CS02 0–1769 °C
BThermocouple (accuracy not guaranteed over 0–399 °C)
B01 400–1800 °CB02 0–1769 °C
EThermocouple
E01 0–800 °CE02 0–1000 °C
NThermocouple
N01 1–1300 °CN02 0–1300 °C
TThermocouple (accuracy held from −199 to 100 °C)
T01 −199.9–400.0 °CT02 −199.9–100.0 °CT03 −199.9–200.0 °CT04 0–350.0 °C
PT100RTD
D01 −199.9–649.0 °CD02 −199.9–200.0 °CD03 −100–50 °CD04 −100–100 °CD05 −100–200 °CD06 0.0–50.0 °CD07 0.0–100 °CD08 0.0–200 °CD09 0.0–300 °CD10 0.0–500 °C
Cu50RTD
P01 −50.0–150.0 °CP02 0.0–150.0 °CP03 0.0–100.0 °CP04 −50.0–0.0 °CP05 −50.0–100.0 °CP06 −50.0–50.0 °CP07 −50–150 °CP08 0–150 °CP09 0–100 °CP10 0–50 °C
0–5VDCStandard signal
401 0.0–100.0
1–5VDCStandard signal
601 0.0–100.0
0–20mAStandard signal, 250 Ω resistor across the terminals
701 0.0–100.0
4–20mAStandard signal, 250 Ω resistor across the terminals
801 0.0–100.0

Linear inputs scale over 0.0–100.0 in engineering units; 0–20 mA and 4–20 mA require a 250 Ω shunt resistor across the terminals.

Alarm type codes

The alarm position in the model code is a letter, not a number. These are the twelve codes the REX, CH and XMT families accept, in the order the factory sheets print them, so a code read off one sheet means the same thing on the next.

CodeAlarm type
NNo alarm
ADeviation high (upper)
BDeviation low (lower)
CDeviation high and low
DBand (deviation range)
EDeviation high, hold action
FDeviation low, hold action
GDeviation high and low, hold action
HProcess high (absolute)
JProcess low (absolute)
KProcess high, hold action
LProcess low, hold action

Codes E, F and G behave like A, B and C but stay latched after the condition clears, until the operator resets the instrument. K and L do the same for the absolute limits.

Codes H, J, K and L compare against an absolute temperature instead of an offset from the set point.

Wiring

The 6311 and 6511 bodies on one sheet: a contactor arrangement, a solid state relay arrangement and an alarm light, each with the electrician's diagram and the terminal reference beside it. The circuit repeats across the sizes; the terminal numbers are printed on each panel.

XMTG / XMTE / XMTD / XMTA-6311 and -6511 · wiring and terminal references

XMTG / XMTE / XMTD / XMTA-6311 and -6511 · wiring and terminal references

Check the jumper before powering up: 2–4 on the contactor build, 2–8 on the alarm build, and nothing on the SSR build, where 5 (+) and 6 (−) are a 12 VDC drive rather than a contact. Sensors: thermocouple red to 11 and blue to 12; three-wire RTD with A on 10, B on 11 and 12.

Download the sheet (PDF)

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

Documents for this family

All documents

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.