Temperature Controllers
XMTG-6511, E thermocouple, SSR output
The XMTG-6511 build with e thermocouple, ssr output.

- Output
- E thermocouple, SSR output
- Bezel
- 72 × 72
- Panel cut-out
- 68 × 68
Technical specifications
| Series | XMT-6000 series panel temperature controller |
|---|---|
| Models | XMTG-6311 / XMTE-6311 / XMTD-6311 / XMTA-6311 |
| Panel sizes | 48×48×65, 48×96×65, 72×72×65 and 96×96×65 mm |
| Panel cutouts | 45×45, 45×92, 68×68 and 92×92 mm |
| Supply | 220 VAC, 50/60 Hz |
| Accuracy | ±1.0% FS |
| Control | PID with autotuning, and on/off with an adjustable differential |
| Input | thermocouple (K or E) on the 1 builds, RTD (Pt100 or Cu50) on the 2 builds |
| Output | relay contact 250 V AC 3 A, or SSR drive |
| Alarm range | full-range setting |
| Operating environment | 0–50 °C, 30–85% RH, no corrosive gas |
Product overview
Part no. SE-XMT-6311industry model XMT-6311
Also known as: XMT-6311 temperature controller · XMT-6311 digital panel controller
The XMT-6311 is the four-bezel member of the XMT-6000 family, and the only one here that reaches the large strip format. One body is built as XMTG-6311, XMTE-6311, XMTD-6311 or XMTA-6311, whichever bezel the panel takes, with two output versions: a relay that switches the heater itself, or a drive signal for a solid state relay. PID with autotuning, an on/off mode with an adjustable differential, and a full-range alarm setting.
Ordering code
XMTG-6511, E thermocouple, SSR output
The XMTG-6511 build with e thermocouple, ssr output.
| Order code | XMTG-6511, E thermocouple, SSR output |
|---|---|
| Bezel (mm) | 72 × 72 |
| Cut-out (mm) | 68 × 68 |
| Output | E thermocouple, SSR output |
| Output terminals | per the case diagram |
| Input | Universal, K thermocouple fitted |
| Alarm | Two relays, A to L selectable |
| Supply | 220VAC 50/60Hz, 10VA |
What it can switch: Selected on the order line; the terminals follow the case diagram for that version
Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.
Other output stages of the same bezel
Key features
- XMTG-6311 / XMTE-6311 / XMTD-6311 / XMTA-6311
- Panel cutouts 45×45, 45×92, 68×68 and 92×92 mm
- 220 VAC, 50/60 Hz supply, ±1.0% FS accuracy
- relay contact 250 V AC 3 A, or SSR drive
- 0–50 °C, 30–85% RH, no corrosive gas
Works with
The parts that go into the same panel and are usually ordered with it.
Four bezels, one instrument
The letter after XMT is the panel size and nothing else: four bezels, one body, and the same depth behind every one of them.
| Model | Panel W×H (mm) | Cutout (mm) |
|---|---|---|
| XMTA | 96 × 96 × 65 mm (1/4 DIN front) | 92 × 92 |
| XMTD | 72 × 72 × 65 mm | 68 × 68 |
| XMTE | 48 × 96 × 65 mm (1/8 DIN front) | 45 × 92 |
| XMTG | 48 × 48 × 65 mm (1/16 DIN front) | 45 × 45 |
Ordering & Selection Guide
Four positions after XMT: the bezel letter, the main output, the alarm count and the input. The series digit sits in the middle of the number and never changes, so it carries no position.
① · Bezel letter
| G | 48 × 48 × 65, cut-out 45 × 45 |
| E | 48 × 96 × 65, cut-out 45 × 92 |
| D | 72 × 72 × 65, cut-out 68 × 68 |
| A | 96 × 96 × 65, cut-out 92 × 92 |
② · Main output
| 3 | Relay contact output (RELAY) |
| 5 | Voltage pulse output (SSR) |
③ · Alarm output
| 1 | One alarm relay |
| 2 | Two alarm relays |
④ · Input type
| 1 | Thermocouple — K or E, named on the order line |
| 2 | RTD — Pt100 or Cu50 |
Worked example
XMTG-6311
A 48 square controller, relay output, one alarm, thermocouple input. Which thermocouple is named on the order line — K and E share the code — but an RTD version would read XMTG-6312.
What ships in each version
Two output versions cover most of the work: a relay that switches the heater directly, and an SSR drive for a heater that is switched by a solid state relay. Both carry PID with autotuning and an on/off mode with an adjustable differential.
- Relay output (63xx)250 V 3 A contact, switching the heater directly through a contactor or on small loads on its own
- SSR drive (65xx)A logic-level signal for an external solid state relay, the version to specify when the load is above the relay rating
Where this sits against the CD and TEL ranges
These are the cheapest of the panel controllers we stock, and the only ones that reach the large strip format. The CD adds a pointer-free dial and a 4–20 mA option; the TEL range is the one with the rotary scale for ovens.
| XMT 6311 | CD | TEL | |
|---|---|---|---|
| Bezels | four, 48 to 96 square | four, 48 to 96 square | one, 96 square |
| Output | relay or SSR drive | relay, SSR drive or 4–20 mA | relay |
| Setting | keys | keys | rotary dial |
| Best for | the widest size range at the lowest cost | a plain setpoint with an analog option | ovens and griddles with a dial |
Input codes and measuring ranges
Most orders use K02 (K 0–400 °C), K06 (K 0–1200 °C), D10 (Pt100 0–500 °C) or 801 (4–20 mA). Expand the full table below for all 14 sensor types and range codes.
③ Full input code table (14 sensor types: K, J, R, S, B, E, N, T, Pt100, Cu50 & 4–20 mA)
| Input | Code and measuring range |
|---|---|
| KThermocouple | K01 0–200 °CK02 0–400 °CK03 0–600 °CK04 0–800 °CK05 0–1000 °CK06 0–1200 °CK07 0–1372 °CK13 0–100 °CK14 0–300 °C |
| JThermocouple | J01 0–200 °CJ02 0–400 °CJ03 0–600 °CJ04 0–800 °CJ05 0–100 °CJ06 0–1200 °C |
| RThermocouple (accuracy not guaranteed over 0–399 °C) | R01 0–1600 °CR02 0–1769 °CR03 0–1350 °C |
| SThermocouple (accuracy not guaranteed over 0–399 °C) | S01 0–1600 °CS02 0–1769 °C |
| BThermocouple (accuracy not guaranteed over 0–399 °C) | B01 400–1800 °CB02 0–1769 °C |
| EThermocouple | E01 0–800 °CE02 0–1000 °C |
| NThermocouple | N01 1–1300 °CN02 0–1300 °C |
| TThermocouple (accuracy held from −199 to 100 °C) | T01 −199.9–400.0 °CT02 −199.9–100.0 °CT03 −199.9–200.0 °CT04 0–350.0 °C |
| PT100RTD | D01 −199.9–649.0 °CD02 −199.9–200.0 °CD03 −100–50 °CD04 −100–100 °CD05 −100–200 °CD06 0.0–50.0 °CD07 0.0–100 °CD08 0.0–200 °CD09 0.0–300 °CD10 0.0–500 °C |
| Cu50RTD | P01 −50.0–150.0 °CP02 0.0–150.0 °CP03 0.0–100.0 °CP04 −50.0–0.0 °CP05 −50.0–100.0 °CP06 −50.0–50.0 °CP07 −50–150 °CP08 0–150 °CP09 0–100 °CP10 0–50 °C |
| 0–5VDCStandard signal | 401 0.0–100.0 |
| 1–5VDCStandard signal | 601 0.0–100.0 |
| 0–20mAStandard signal, 250 Ω resistor across the terminals | 701 0.0–100.0 |
| 4–20mAStandard signal, 250 Ω resistor across the terminals | 801 0.0–100.0 |
Linear inputs scale over 0.0–100.0 in engineering units; 0–20 mA and 4–20 mA require a 250 Ω shunt resistor across the terminals.
Alarm type codes
The alarm position in the model code is a letter, not a number. These are the twelve codes the REX, CH and XMT families accept, in the order the factory sheets print them, so a code read off one sheet means the same thing on the next.
| Code | Alarm type |
|---|---|
| N | No alarm |
| A | Deviation high (upper) |
| B | Deviation low (lower) |
| C | Deviation high and low |
| D | Band (deviation range) |
| E | Deviation high, hold action |
| F | Deviation low, hold action |
| G | Deviation high and low, hold action |
| H | Process high (absolute) |
| J | Process low (absolute) |
| K | Process high, hold action |
| L | Process low, hold action |
Codes E, F and G behave like A, B and C but stay latched after the condition clears, until the operator resets the instrument. K and L do the same for the absolute limits.
Codes H, J, K and L compare against an absolute temperature instead of an offset from the set point.
Wiring
The 6311 and 6511 bodies on one sheet: a contactor arrangement, a solid state relay arrangement and an alarm light, each with the electrician's diagram and the terminal reference beside it. The circuit repeats across the sizes; the terminal numbers are printed on each panel.
XMTG / XMTE / XMTD / XMTA-6311 and -6511 · wiring and terminal references
Check the jumper before powering up: 2–4 on the contactor build, 2–8 on the alarm build, and nothing on the SSR build, where 5 (+) and 6 (−) are a 12 VDC drive rather than a contact. Sensors: thermocouple red to 11 and blue to 12; three-wire RTD with A on 10, B on 11 and 12.
One page per order code
Every code this family ships, with the bezel, the output stage and the terminals that output uses.
XMTD-6311
72 × 72mm · cut-out 68 × 68mm
XMTG-6311
72 × 72mm · cut-out 68 × 68mm
XMTG-6511
72 × 72mm · cut-out 68 × 68mm
XMTE-6311
72 × 72mm · cut-out 68 × 68mm
XMTE-6511
72 × 72mm · cut-out 68 × 68mm
XMTA-6311
72 × 72mm · cut-out 68 × 68mm
XMTA-6511
72 × 72mm · cut-out 68 × 68mm
Documents for this family
- XMT-1000 series wiring207 KB · 2026-11-19
- XMT-6000 (6311 / 6511) wiring325 KB · 2026-11-18
- XMT-8000 series wiring308 KB · 2026-11-18
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 3 years
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
TEL96-9001 or TEL96-2001: Choosing the Right Oven Temperature Controller
The TEL96 series is a 96 x 96 mm on/off oven temperature controller built around a K-type thermocouple input and a 10 A relay contact. It is made in two versions, the TEL96-9001…
Read guide Technical Guides · 2026-08-23How to Wire REX-C100, REX-C700 and REX-C400/C900 Temperature Controllers
English wiring diagrams for REX-series temperature controllers, including relay, AC contactor, SSR, K-type thermocouple and 3-wire PT100 connections.
Read guide Technical Guides · 2025-04-15How to Wire REX-C100/C400/C700 Temperature Controllers with Relay and SSR Output
This blog provides a comprehensive guide on wiring REX series temperature controllers, including the C100, C400, and C700 models. It explains both relay and solid-state relay…
Read guideRelated models
All Temperature Controllers
XMT M / MS Single-Display Controller — 48×48 to 96×96mm
SE-XMT-MS
One big display and three keys. The measurement fills the front, the mode key steps between the alarm limit and the output limit, and a lamp beside…
View details
8411 Series PID Temperature Controllers (XMTG / XMTE / XMTD / XMTA fronts)
SE-XMT-8411
The 8000 series is the smaller series' body with a wider instrument behind the bezel: one input that takes the whole thermocouple and RTD range, a…
View details
XMT-1000 Series Digital Temperature Controller
SE-XMT-1000
The measured value on the display, the setpoint on a three-digit thumbwheel switch underneath. No menu, no key sequence: whoever is standing at the…
View details
XMTD Series Digital Temperature Controller
SE-XMTD
The XMTD-2001 and XMTD-2201 are 72×72 mm panel-mount On/Off temperature controllers built for straightforward, menu-free operation. Operators set the…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.