M6 M8 Screw Type Thermocouple Temperature Sensor Probe
M6 x 1.0 and M8 x 1.25 threaded temperature sensor probes with braided high-temperature lead and U-type terminals.

Thermocouples & RTD Sensors

M6 / M8 Threaded Temperature Sensor Probe (K, E Thermocouple or Pt100 RTD)

Threaded bolt-on temperature sensor for heater bands, moulds, platens and machine bodies. Choose a K or E type thermocouple element or a 3-wire Pt100 RTD element, an M6 x 1.0 or M8 x 1.25 metric thread, and a braided high-temperature lead cut to your installation length.

  • Threaded ring probe bolts directly onto a heater band, platen or machine body for close thermal contact with the measured surface.
  • Element options: K type thermocouple, E type thermocouple, or 3-wire Pt100 RTD — specify to match the input of your temperature controller.
  • M6 x 1.0 and M8 x 1.25 metric threads are stocked; other thread sizes are produced to order.
  • Braided high-temperature lead resists abrasion and mechanical damage on moving or vibrating machinery.
  • U-type crimped terminals land straight on controller screw terminals with no extra preparation.
  • Standard lead lengths 0.5, 1, 1.5, 2 and 3 m; any length from 0.2 m to 5 m is produced to order.
  • Used on plastic extruders and injection machines, packaging sealing bars, ovens, moulds and boiler equipment.
Stock / sample dispatch
3–5 working days
Warranty
12 months
OEM
Supported
Shipping
Worldwide export

Technical specifications

Product NameM6 / M8 Threaded Temperature Sensor Probe
Element TypeK type thermocouple / E type thermocouple / Pt100 RTD (3-wire)
Measuring Range (K type)0–800°C
Measuring Range (E type)0–600°C
Measuring Range (Pt100 RTD)-50–400°C
Thread SizeM6 x 1.0 / M8 x 1.25 (metric); other threads to order
Probe MaterialStainless steel threaded ring / bolt probe
Lead CableBraided high-temperature cable, shielded option available
Lead LengthStandard 0.5 / 1 / 1.5 / 2 / 3 m; 0.2–5 m to order
Terminal TypeU-type crimped terminals
Installation MethodBolted / screw fixed to the measured surface
Compatible EquipmentPID temperature controllers with K, E or Pt100 input
CustomizationElement type, thread size, lead length, terminal style

Product Details and Custom Options

Overview of the M6 threaded thermocouple construction, sensor options, thread dimensions, cable and terminal configurations.

M6 Thermocouple Product Details and Custom Options
M6 threaded thermocouple product construction, dimensions and customizable configuration options.

Frequently asked questions

Is Pt100 a thermocouple?

No. Pt100 is a platinum resistance temperature detector (RTD) wired with three leads, while K and E are thermocouples that generate a millivolt signal. All three are offered in the same threaded body, but the controller input type must be set to match the element fitted.

Which element should I order — K, E or Pt100?

Use K type for general heating up to 800°C, E type where you need more signal per degree up to 600°C, and Pt100 for accuracy and stability below 400°C. If the controller is already installed, order the element its input is configured for.

What thread sizes are available?

M6 x 1.0 and M8 x 1.25 metric threads are standard. Other thread sizes, including inch threads, are produced to order — send the tapped hole size or a sample with your enquiry.

Can the lead length be customised?

Yes. Standard lengths are 0.5, 1, 1.5, 2 and 3 m, and any length from 0.2 m to 5 m can be produced. Alternative terminals and connectors are also available.

The temperature reading falls when the machine heats up. Why?

The two thermocouple leads are reversed. Swap them at the controller terminals and the reading will follow the process correctly.

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.