Thermocouples & RTD Sensors
M6 / M8 Threaded Temperature Sensor Probe (K, E Thermocouple or Pt100 RTD)
M6 x 1.0 and M8 x 1.25 threaded probes with K type, E type thermocouple or 3-wire Pt100 element, braided high-temperature lead and U-type terminals.

- Resolution
- 1°C on K and E; 0.1°C on Pt100
- Product type
- Bolt-on sensor for a tapped M6 or M8 hole in a heater band, platen, mould or machine body
- Element
- K type thermocouple / E type thermocouple / Pt100 RTD (3-wire)
- Measuring range (K type)
- 0–800°C
Technical specifications
| Product type | Bolt-on sensor for a tapped M6 or M8 hole in a heater band, platen, mould or machine body |
|---|---|
| Element | K type thermocouple / E type thermocouple / Pt100 RTD (3-wire) |
| Measuring range (K type) | 0–800°C |
| Measuring range (E type) | 0–600°C |
| Measuring range (Pt100 RTD) | -50–400°C |
| Tolerance | ±1°C for the assembled probe — tighter than IEC 60584 Class 1 for K, so say whether the class or this figure governs |
| Resolution | 1°C on K and E; 0.1°C on Pt100 |
| Response time | About 1s |
| Body | 6mm probe tip, 9.5mm threaded length, 10mm hex across flats, 26mm overall |
| Thread | M6 × 1.0 metric fine / M6 × 1.25 imperial coarse / M8 × 1.25; M10 and other threads to order |
| Lead length | Standard 0.5 / 1 / 1.5 / 2 / 3 m; 0.2–5 m to order |
| Lead insulation | High-density stainless-steel braid over a shielded high-temperature core |
| Termination | 4mm U-type crimped fork terminals; on the thermocouple versions the leads follow the polarity marked on the terminal block: under ANSI colour coding the negative lead is red and the positive lead takes the colour of the type (yellow for K, blue for T, white for J), and the Pt100 leads land as the terminal diagram shows; pin-type terminals to order |
| Protection | IP55 |
| Mounting | Screwed into a tapped hole; the thread is the only fixing, so the hole has to be the right size and cut cleanly |
| Typical use | Heater bands, extrusion barrels, platens, sealing bars, moulds and boiler equipment |
| Wiring | Two-wire for K and E, three-wire for Pt100. Confirm the colour code on the lead before wiring. |
Product overview
Part no. SE-TC-M6M8industry model TC-M6M8
Also known as: M6 / M8 temperature sensor · M6 / M8 probe
A short bolt-on sensor. The threaded body screws into a tapped M6 or M8 hole in a heater band, platen, mould or machine body, so the element sits in the metal rather than in the air beside it. The whole body is 26mm long, which is what lets it fit where a probe with a terminal head will not.
Key features
- K, E or Pt100 in the same body — specify the element to match the controller input.
- M6 × 1.0 and M8 × 1.25 metric threads are stocked; M10 and inch threads are produced to order.
- About 1s response, ±1°C on the assembled probe and IP55 — enough to survive washdown and coolant spray.
- Braided lead from 0.2 m to 5 m; standard lengths 0.5, 1, 1.5, 2 and 3 m.
- U-type crimped terminals land straight on the controller's screw terminals with no preparation.
Works with
The parts that go into the same panel and are usually ordered with it.
How to specify
Three choices fix the part: element, thread and lead length. MB-K-06-100 is a K type element in an M6 × 1.0 body on a 1 m braided lead.
Fixed in this familyChosen when ordering
| Position | Code | Selects |
|---|---|---|
| Family | MB | Bolt-on sensor, metric thread |
| Element | K | K type thermocouple |
| E | E type thermocouple | |
| P | Pt100 RTD, 3-wire | |
| Thread | 06 | M6 × 1.0 |
| 08 | M8 × 1.25 | |
| Lead, cm | 50 | 0.5 m lead |
| 100 | 1 m lead | |
| 150 | 1.5 m lead | |
| 200 | 2 m lead | |
| 300 | 3 m lead |
- The thread is what has to match the machine, so measure the tapped hole before ordering. The body is only 26 mm long, so the hole depth decides how far the tip reaches.
- Any lead from 20 to 500 cm is produced; the code carries the five standard lengths. M10 and inch threads, other terminal styles and shielded lead are quoted on request.
Dimensions
L, the thread and the lead length are the three dimensions that have to be settled before a probe can be designed into a machine. Everything else on these sensors is fixed by the family.
Design points
- Braided shield — a high-density stainless braid over the core keeps the signal clean beside contactors and drives.
- Welded, sealed tip — the sensing end is welded closed rather than crimped, so it stays sealed as it heats and cools.
- Movable screw — the screw runs on the threaded body instead of being fixed to the lead, so it can be backed off and reset when the wall thickness changes.
- Two pitches — M6 × 1.0 metric fine is standard; M6 × 1.25 imperial coarse is produced to order.
- Terminals — 4mm U-type forks, red on + and blue on −, land on a controller's screw terminals with no preparation.
Product photos




Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Frequently asked questions
Is Pt100 a thermocouple?
No. Pt100 is a platinum resistance temperature detector (RTD) wired with three leads, while K and E are thermocouples that generate a millivolt signal. All three are offered in the same threaded body, but the controller input type must be set to match the element fitted.
Which element should I order — K, E or Pt100?
Use K type for general heating up to 800°C, E type where you need more signal per degree up to 600°C, and Pt100 for accuracy and stability below 400°C. If the controller is already installed, order the element its input is configured for.
What thread sizes are available?
M6 × 1.0 metric fine and M8 × 1.25 are standard. M6 × 1.25 imperial coarse and other thread sizes are produced to order — send the tapped hole size or a sample with your enquiry, and say which pitch the hole takes.
Can the lead length be customised?
Yes. Standard lengths are 0.5, 1, 1.5, 2 and 3 m, and any length from 0.2 m to 5 m can be produced. Alternative terminals and connectors are also available.
The temperature reading falls when the machine heats up. Why?
The two thermocouple leads are reversed. Swap them at the controller terminals and the reading will follow the process correctly.
Certification and model-specific options
Certification
If CE or RoHS documentation is required, identify the exact model and ask us to confirm which current documents apply with the quotation. ATEX / IECEx zone-rated assemblies are not listed in this range; confirm requirements before specifying.
OEM and private label
Private-label marking or packaging may be available for selected probe models. The marking locations, supported construction and minimum quantity are confirmed against the model and order in the quotation.
What can be changed
Thread, sheath, lead insulation, terminal style and insertion length depend on the probe model and construction. Send the drawing or installation dimensions and we will confirm available options and quote accordingly.
Tolerance has to be stated
A tolerance class is not implied by a part number. Say Class 1 or Class 2 for K and E type (IEC 60584), Class A or B for Pt100 (IEC 60751), on the order — otherwise the probe is built to the standard class and the loop may not hold the accuracy you designed for.
Pressure
None of these probes is rated for pressure service. If the sensor goes into a pressurised pipe or vessel, ask for a thermowell and we will supply a probe that fits it — a bare sheath in a pressurised line is a leak waiting to happen.
Related guides
How to Choose a Threaded Temperature Sensor: K, E Thermocouple or Pt100 RTD
A selection and installation guide for M6 / M8 threaded temperature sensor probes: how thermocouples and RTDs differ, which element to specify, how thread size and mounting affect…
Read guide Technical Guides · 2026-08-27How to Wire CH102, CH402, CH702 and CH902 PID Temperature Controllers
A practical wiring guide for CH102, CH402, CH702 and CH902 PID temperature controllers, covering power, AC contactor and SSR control, thermocouple and Pt100 sensors, alarms and…
Read guide Technical Guides · 2026-08-23How to Wire REX-C100, REX-C700 and REX-C400/C900 Temperature Controllers
English wiring diagrams for REX-series temperature controllers, including relay, AC contactor, SSR, K-type thermocouple and 3-wire PT100 connections.
Read guideRelated models
All Thermocouples & RTD Sensors
Probe-Type Stainless Steel Thermocouple Temperature Sensor (K, E Thermocouple or PT100 / CU50 RTD)
SE-TC-SS
An M12 threaded stainless probe for a tapped hole in a platen, barrel, mould, duct or oven wall, where the tip has to sit in the metal rather than in…
View details
Ø8 Threaded Probe Thermocouple with Braided Shielded Lead (K, E or Pt100)
SE-TC-THREADED
A Ø8 stainless sheath on a fixed external thread, supplied on a metal-braided shielded lead. Ø8 is the size that drops into the tapped hole already…
View details
Simple-Type Thermocouple or RTD | 4 × 40mm Probe, Clamp Mount, K / E / Pt100 / Cu50
SE-TC-4X40
The plainest sensor in the range: a 4 × 40 mm stainless probe on a braided lead, clamped against the part instead of screwed into it. Bolt the clamp…
View details
Sheathed Thermocouple or Pt100 RTD | Cast Aluminium Head, G1/2, 6mm Sheath
SE-TC-WRNK236
One mechanical version, two elements. The WRNK-236 takes a K type thermocouple for readings up to 0–800 °C; the WZP-236 takes a Pt100 for the colder…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.