Temperature Controllers
TS700 Temperature, Time and Count Controller
TS700 controller for hot-stamping presses: 0–999°C control, a timer and a cycle counter on one 72×72mm panel, plus a 30A relay.

- Panel size
- 72×72mm
- Panel cutout
- 68×68mm
- Control output
- Built-in 30A relay for direct heater switching, or an SSR drive for an external solid state relay
- Supply voltage
- 220VAC, 50/60Hz
Order codes of this series
This series is built in more than one version. Each has its own page with the complete order code, the output stage it carries and what that stage can switch; the case, the cut-out and the supply stay the same.
| Order code | Output stage | Bezel (mm) | Cut-out | Open |
|---|---|---|---|---|
| TS700 relay version | Internal 30 A power relay | panel mount, 275 V input | as marked on the case | TS700 relay version → |
| TS700 SSR version | External solid state relay drive | panel mount, 275 V input | as marked on the case | TS700 SSR version → |
Technical specifications
| Series | TS700 (temperature, time and count controller) |
|---|---|
| Models | TS700-30A with the built-in relay, or TS700-SSR with the solid state relay drive |
| Functions | Temperature control, timer and counter on one front panel |
| Display | LED seven-segment display with separate temperature, time and count readouts |
| Control method | PID with auto-tuning, ON/OFF and position control |
| Input | Thermocouple; K as standard. Confirm the input code on the unit before ordering |
| Temperature range | 0–999°C |
| Control output | Built-in 30A relay for direct heater switching, or an SSR drive for an external solid state relay |
| Relay contact rating | 30A relay contact, 1500W resistive load |
| External switch input | DC 6–36V, two-wire proximity switch as standard; passive contact input on the relay version |
| Time output | Separate contact on terminals 5 and 6, closed for the duration of the dwell, for an alarm lamp or a solenoid |
| Fitted options | Buzzer and emergency-stop button are optional on this model; the standard version ships without them |
| Supply voltage | 220VAC, 50/60Hz |
| Accuracy | ±1°C |
| Parameter storage | A changed setpoint is written to memory only when the RESET key is pressed again |
| Panel size | 72×72mm |
| Panel cutout | 68×68mm |
| Weight | 0.158kg (relay) / 0.134kg (solid state) |
| Mounting | Panel mount, base-bolt clamp |
| Certification | CE |
| Jumper | terminals 2-3 and 2-5 in the relay version; terminal 2-5 only in the SSR version |
Product overview
Part no. SE-TS700
Also known as: TS700 temperature controller · TS700 PID controller · TS700 controlador de temperatura
The TS700 puts the three things a hot-stamping press needs on one 72×72mm panel: a temperature loop that reaches 0–999°C, a timer that holds the dwell, and a counter that follows the machine cycle from a two-wire proximity switch instead of being reset by hand. The heater is driven either by the built-in 30A relay — up to 1500W directly, no contactor — or by an external solid state relay through the SSR drive version. A separate time-output contact on terminals 5 and 6 switches an alarm lamp when the dwell ends, so the operator sees the cycle without watching the display.
Key features
- Temperature, timer and counter on one front panel
- Temperature range 0–999°C, displayed to ±1°C
- Built-in 30A relay for heaters up to 1500W, or an SSR drive version for an external solid state relay
- DC 6–36V input for a two-wire proximity switch, so the counter follows the machine cycle
- Time-output contact on terminals 5 and 6 for an alarm lamp at the end of the dwell
- Setpoint is stored only after the RESET key is pressed, so a brush against the keys cannot change the process
- Buzzer and emergency-stop button available to order; the standard version ships without them
- 72×72mm front, 68×68mm cutout, base-bolt clamp
- CE marked
Works with
The parts that go into the same panel and are usually ordered with it.
Model versions
Three versions ship from the same case. The difference is how the heater is switched and what is fitted to the front.
| Version | Heater switching | Switch input | Weight | Lead |
|---|---|---|---|---|
| Built-in 30A relay | Relay, direct to the heater | DC 6–36V proximity switch, passive contact | 0.158kg | 1m |
| External solid state relay | SSR drive | DC 6–36V proximity switch | 0.134kg | 1.5m |
| No buzzer, no emergency stop | Relay or SSR drive | Two-wire proximity switch as standard | 0.158kg | 2m |
Terminal layout and wiring
Eleven terminals: 1–6 along the bottom edge and 7–11 down the right-hand side, numbered as they are moulded on the case. The same terminal map and the same drawing cover the TS700 and the TS700-X — the two models differ in the display, not in the wiring. Use the relay version when the heater load stays inside the 30 A contact. Use the SSR version when it does not, or when the load has to switch frequently - the SSR is sized for the heater on its own.
TS700-30A / TS700-X
Built-in relay — the heater switches inside the case
- 1Neutral to 1, live to 2. Both are 220VAC; blue on 1 and red on 2.
- 2Fit the 2–3 and 2–5 jumpers. They are wires you add, not internal links: without them the relay and the time contact have no live feed.
- 3Heater between 4 and neutral. Terminal 3 is the relay common, so 4 closes to live and the heater sees the full supply.
- 4Alarm lamp between 6 and neutral. Terminals 5–6 close for the dwell and open when the timer ends.
- 5Start button on 7 and 8 — closing it starts the timing cycle. K thermocouple on 10 (+) and 11 (−). Terminal 9 stays empty.
TS700-SSR version
External solid state relay — the load current stays outside
- 1Neutral to 1, live to 2, and keep the 2–5 jumper so the time contact still has a live feed.
- 2On this version 3 and 4 are a DC control output, not a contact: 3 goes to the SSR + and 4 to the SSR −.
- 3Live goes to one SSR output terminal, the heater to the other, and the heater return to neutral. The switching current never enters the controller.
- 4Terminals 5–6, 7–8 and 10–11 are wired exactly as on the relay version.
Setting the controller
- A changed setpoint is written to memory only when the RESET key is pressed again. Change the value, press RESET, and the new setpoint survives a power cut.
- Set a value with the decrement and increment keys; hold either key and the value runs faster instead of stepping one digit at a time.
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 3 years
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Related guides
How to Choose a TCN4 Temperature Controller: Reading the Code Behind Size, Output and Range
The TCN4 order code carries five choices after a fixed prefix, and three of them — cutout, output build and alarm count — decide whether the unit fits the panel and drives the…
Read guide Technical Guides · 2026-03-02TC3-401T Celsius and Fahrenheit Setup Guide
Step-by-step guide to switching the Strong Electric TC3-401T temperature and time controller between Celsius and Fahrenheit: unlock the LCK parameter, set the CF unit code,…
Read guide FAQ · 2025-04-24How to Use the TC3-401T Front Panel for Temperature and Time Control
This blog walks you through the TC3-401T temperature timer controller’s front panel, explaining each function key, dual display mode, and how to adjust temperature and time…
Read guideRelated models
All Temperature Controllers
TS700-X LED Temperature, Time & Count — 30A
SE-TS700-X
72×72mm · 68×68mm
View details
TS400 Temperature, Time & Count Controller — 48×96mm
SE-TS400
48×96mm (1/8 DIN) · 45×92mm · 85mm behind the bezel
View details
TS600 Touch Screen Temperature Controller — 72×72mm
SE-TS600
72×72mm · 68×68mm
View details
TS800 Touch Controller with Emergency Stop
SE-TS800
The TS800 puts temperature, dwell time and a five-digit counter on one LCD touch panel, which is what a hot-stamping or heat-transfer press actually…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.