Temperature Controllers

TS700 Temperature, Time and Count Controller

TS700 controller for hot-stamping presses: 0–999°C control, a timer and a cycle counter on one 72×72mm panel, plus a 30A relay.

TS700 temperature, time and count controller showing 16 °C, a 3 s timer and a five-digit counter
TS700 with all three readouts lit — 16 °C, a 3 s timer and a five-digit counter; 72×72mm front on a 68×68mm cutout
Panel size
72×72mm
Panel cutout
68×68mm
Control output
Built-in 30A relay for direct heater switching, or an SSR drive for an external solid state relay
Supply voltage
220VAC, 50/60Hz
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Order codes of this series

This series is built in more than one version. Each has its own page with the complete order code, the output stage it carries and what that stage can switch; the case, the cut-out and the supply stay the same.

Order codeOutput stageBezel (mm)Cut-outOpen
TS700 relay versionInternal 30 A power relaypanel mount, 275 V inputas marked on the caseTS700 relay version →
TS700 SSR versionExternal solid state relay drivepanel mount, 275 V inputas marked on the caseTS700 SSR version →

Technical specifications

SeriesTS700 (temperature, time and count controller)
ModelsTS700-30A with the built-in relay, or TS700-SSR with the solid state relay drive
FunctionsTemperature control, timer and counter on one front panel
DisplayLED seven-segment display with separate temperature, time and count readouts
Control methodPID with auto-tuning, ON/OFF and position control
InputThermocouple; K as standard. Confirm the input code on the unit before ordering
Temperature range0–999°C
Control outputBuilt-in 30A relay for direct heater switching, or an SSR drive for an external solid state relay
Relay contact rating30A relay contact, 1500W resistive load
External switch inputDC 6–36V, two-wire proximity switch as standard; passive contact input on the relay version
Time outputSeparate contact on terminals 5 and 6, closed for the duration of the dwell, for an alarm lamp or a solenoid
Fitted optionsBuzzer and emergency-stop button are optional on this model; the standard version ships without them
Supply voltage220VAC, 50/60Hz
Accuracy±1°C
Parameter storageA changed setpoint is written to memory only when the RESET key is pressed again
Panel size72×72mm
Panel cutout68×68mm
Weight0.158kg (relay) / 0.134kg (solid state)
MountingPanel mount, base-bolt clamp
CertificationCE
Jumperterminals 2-3 and 2-5 in the relay version; terminal 2-5 only in the SSR version

Product overview

Part no. SE-TS700

Also known as: TS700 temperature controller · TS700 PID controller · TS700 controlador de temperatura

The TS700 puts the three things a hot-stamping press needs on one 72×72mm panel: a temperature loop that reaches 0–999°C, a timer that holds the dwell, and a counter that follows the machine cycle from a two-wire proximity switch instead of being reset by hand. The heater is driven either by the built-in 30A relay — up to 1500W directly, no contactor — or by an external solid state relay through the SSR drive version. A separate time-output contact on terminals 5 and 6 switches an alarm lamp when the dwell ends, so the operator sees the cycle without watching the display.

Key features

  • Temperature, timer and counter on one front panel
  • Temperature range 0–999°C, displayed to ±1°C
  • Built-in 30A relay for heaters up to 1500W, or an SSR drive version for an external solid state relay
  • DC 6–36V input for a two-wire proximity switch, so the counter follows the machine cycle
  • Time-output contact on terminals 5 and 6 for an alarm lamp at the end of the dwell
  • Setpoint is stored only after the RESET key is pressed, so a brush against the keys cannot change the process
  • Buzzer and emergency-stop button available to order; the standard version ships without them
  • 72×72mm front, 68×68mm cutout, base-bolt clamp
  • CE marked

Works with

The parts that go into the same panel and are usually ordered with it.

Model versions

Three versions ship from the same case. The difference is how the heater is switched and what is fitted to the front.

VersionHeater switchingSwitch inputWeightLead
Built-in 30A relayRelay, direct to the heaterDC 6–36V proximity switch, passive contact0.158kg1m
External solid state relaySSR driveDC 6–36V proximity switch0.134kg1.5m
No buzzer, no emergency stopRelay or SSR driveTwo-wire proximity switch as standard0.158kg2m

Terminal layout and wiring

Eleven terminals: 1–6 along the bottom edge and 7–11 down the right-hand side, numbered as they are moulded on the case. The same terminal map and the same drawing cover the TS700 and the TS700-X — the two models differ in the display, not in the wiring. Use the relay version when the heater load stays inside the 30 A contact. Use the SSR version when it does not, or when the load has to switch frequently - the SSR is sized for the heater on its own.

TS700 sheet: operation notes, the 1-11 terminal schematic, the internal relay wiring and the external SSR wiring
Terminal reference, 1–11. Terminal 9 is not used.

TS700-30A / TS700-X

Built-in relay — the heater switches inside the case

Built-in relay version: the heater hangs off terminal 4, the lamp off terminal 6, and both return to neutral.
  1. 1Neutral to 1, live to 2. Both are 220VAC; blue on 1 and red on 2.
  2. 2Fit the 2–3 and 2–5 jumpers. They are wires you add, not internal links: without them the relay and the time contact have no live feed.
  3. 3Heater between 4 and neutral. Terminal 3 is the relay common, so 4 closes to live and the heater sees the full supply.
  4. 4Alarm lamp between 6 and neutral. Terminals 5–6 close for the dwell and open when the timer ends.
  5. 5Start button on 7 and 8 — closing it starts the timing cycle. K thermocouple on 10 (+) and 11 (−). Terminal 9 stays empty.

TS700-SSR version

External solid state relay — the load current stays outside

SSR version: 3 and 4 drive the relay, and the heater is switched on the live side outside the controller.
  1. 1Neutral to 1, live to 2, and keep the 2–5 jumper so the time contact still has a live feed.
  2. 2On this version 3 and 4 are a DC control output, not a contact: 3 goes to the SSR + and 4 to the SSR −.
  3. 3Live goes to one SSR output terminal, the heater to the other, and the heater return to neutral. The switching current never enters the controller.
  4. 4Terminals 5–6, 7–8 and 10–11 are wired exactly as on the relay version.

Setting the controller

  • A changed setpoint is written to memory only when the RESET key is pressed again. Change the value, press RESET, and the new setpoint survives a power cut.
  • Set a value with the decrement and increment keys; hold either key and the value runs faster instead of stepping one digit at a time.

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.