Temperature Controllers

TS700-X LED Temperature, Time and Count Controller

TS700-X panel-mount controller with a three-colour LED display, 0–999°C range, a 30A relay rated 1500W and parameter memory that survives power-off.

TS700-X LED temperature, time and count controller
TS700-X, LED version — 72×72mm front on a 68×68mm cutout
Panel size
72×72mm
Panel cutout
68×68mm
Control output
Relay output
Supply voltage
220VAC, 50/60Hz
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

ModelTS700-X
FunctionsTemperature control, timer and counter on one instrument
DisplayLED display with colour-separated temperature, time and count readouts
Parameter memorySettings are held after power-off, so a machine does not need re-entering after a break
Control methodTemperature control with a settable timer and cycle counter
Temperature range0–999°C
Control outputRelay output
Relay contact rating30A relay contact, 1500W resistive load
Supply voltage220VAC, 50/60Hz
Accuracy±1°C
Panel size72×72mm
Panel cutout68×68mm
MountingPanel mount
CertificationCE

Product overview

Part no. SE-TS700-X

Also known as: TS700-X temperature controller · TS700-X PID controller · TS700-X controlador de temperatura

The TS700-X is the LED version of the TS700 platform: the same temperature, time and count functions, read on a colour-separated LED display rather than a segment display, with the parameter memory holding every setting through a power cut so a machine does not need re-entering after a shift break. The range runs to 0–999°C with ±1°C resolution, the output is a 30A relay rated for 1500W, the supply is 220VAC, and the 72×72mm case mounts through a 68×68mm cutout with a base-bolt clamp.

Key features

  • LED display with colour-separated temperature, time and count readouts
  • Parameter memory holds every setting after power-off
  • Temperature, timer and counter in one instrument
  • Temperature range 0–999°C, displayed to ±1°C
  • 30A relay output rated for a 1500W load
  • 220VAC supply
  • 72×72mm front, 68×68mm cutout, base-bolt clamp
  • CE marked

Works with

The parts that go into the same panel and are usually ordered with it.

Model versions

Three versions ship from the same case. The difference is how the heater is switched and what is fitted to the front.

VersionHeater switchingSwitch inputWeightLead
Built-in 30A relayRelay, direct to the heaterDC 6–36V proximity switch, passive contact0.158kg1m
External solid state relaySSR driveDC 6–36V proximity switch0.134kg1.5m
No buzzer, no emergency stopRelay or SSR driveTwo-wire proximity switch as standard0.158kg2m

Terminal layout and wiring

Eleven terminals: 1–6 along the bottom edge and 7–11 down the right-hand side, numbered as they are moulded on the case. The same terminal map and the same drawing cover the TS700 and the TS700-X — the two models differ in the display, not in the wiring. Use the relay version when the heater load stays inside the 30 A contact. Use the SSR version when it does not, or when the load has to switch frequently - the SSR is sized for the heater on its own.

TS700 sheet: operation notes, the 1-11 terminal schematic, the internal relay wiring and the external SSR wiring
Terminal reference, 1–11. Terminal 9 is not used.

TS700-30A / TS700-X

Built-in relay — the heater switches inside the case

Built-in relay version: the heater hangs off terminal 4, the lamp off terminal 6, and both return to neutral.
  1. 1Neutral to 1, live to 2. Both are 220VAC; blue on 1 and red on 2.
  2. 2Fit the 2–3 and 2–5 jumpers. They are wires you add, not internal links: without them the relay and the time contact have no live feed.
  3. 3Heater between 4 and neutral. Terminal 3 is the relay common, so 4 closes to live and the heater sees the full supply.
  4. 4Alarm lamp between 6 and neutral. Terminals 5–6 close for the dwell and open when the timer ends.
  5. 5Start button on 7 and 8 — closing it starts the timing cycle. K thermocouple on 10 (+) and 11 (−). Terminal 9 stays empty.

TS700-SSR version

External solid state relay — the load current stays outside

SSR version: 3 and 4 drive the relay, and the heater is switched on the live side outside the controller.
  1. 1Neutral to 1, live to 2, and keep the 2–5 jumper so the time contact still has a live feed.
  2. 2On this version 3 and 4 are a DC control output, not a contact: 3 goes to the SSR + and 4 to the SSR −.
  3. 3Live goes to one SSR output terminal, the heater to the other, and the heater return to neutral. The switching current never enters the controller.
  4. 4Terminals 5–6, 7–8 and 10–11 are wired exactly as on the relay version.

Setting the controller

  • A changed setpoint is written to memory only when the RESET key is pressed again. Change the value, press RESET, and the new setpoint survives a power cut.
  • Set a value with the decrement and increment keys; hold either key and the value runs faster instead of stepping one digit at a time.

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the TS700-X need?

72×72mm. The cut-out is 68×68mm

What output options does the TS700-X have?

Relay output

What supply voltage does the TS700-X need?

220VAC, 50/60Hz

How accurate is the TS700-X?

±1°C

What is the temperature range?

0–999°C

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.