Temperature Controllers

TS800 Series Touch Screen Temperature, Time and Count Controller

TS800 LCD touch-screen controller: temperature, dwell timer and counter on one panel, a 30A relay or SSR drive, and a dedicated e-stop input.

TS800 touch temperature controller, screen lit, showing a setpoint, a dwell time and the counter row
TS800 with the display lit — die temperature, dwell and machine count on one panel. The emergency stop is an external switch on terminals 7 and 8, not a button on the front
Control output
Built-in 30A relay for direct heater switching, or a DC drive for an external solid state relay
Supply voltage
220VAC, 50/60Hz
Input
Thermocouple; K as standard, E available to order. Confirm the input code on the unit before ordering
Temperature range
0–400°C
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesTS800 (LCD touch-screen temperature, time and count controller)
ModelsTS800-30A with the built-in relay, or TS800-SSR with the output for an external solid state relay
FunctionsTemperature control, timer and counter on one panel, with inputs for an emergency-stop switch and a timer pushbutton
DisplayLCD touch panel with separate temperature, time and count readouts
Control methodPID with auto-tuning, ON/OFF and position control
InputThermocouple; K as standard, E available to order. Confirm the input code on the unit before ordering
Temperature range0–400°C
Control outputBuilt-in 30A relay for direct heater switching, or a DC drive for an external solid state relay
Relay contact rating30A relay contact, 1500W resistive load
Solid state relay driveDC drive for an external solid state relay, 3–32VDC
External switch inputDC 6–36V, two-wire proximity switch
Emergency stopA separate pair of terminals for a normally-closed mushroom switch. It is not a button on the front panel — the switch is mounted where the operator can reach it and the controller cuts the heating output when the circuit opens
Timer triggerA second pair of terminals for a pushbutton or a proximity switch; closing the circuit starts the timer
Supply voltage220VAC, 50/60Hz
Accuracy±1°C
Response time1s
Parameter retentionSetpoints and the counter value are held after power-off
MountingPanel mount, flush bezel
CertificationCE

Product overview

Part no. SE-TS800

Also known as: TS800 temperature controller · TS800 PID controller · TS800 controlador de temperatura

The TS800 puts temperature, dwell time and a five-digit counter on one LCD touch panel, which is what a hot-stamping or heat-transfer press actually needs: the operator sets the die temperature, sets the dwell, and watches the count without reading three separate instruments. The heating output is either a built-in 30A relay or a solid state relay drive for an external module, and both versions take a DC 6–36V two-wire proximity switch as the part-present signal. The emergency stop is deliberately not on the instrument face — terminals 7 and 8 take a normally-closed mushroom switch mounted where the operator can reach it, and the controller drops the heating output the moment that circuit opens.

Key features

  • Temperature, dwell timer and counter on one LCD touch panel
  • Emergency stop wired to its own terminal pair — the mushroom switch sits where the operator can reach it, not on the instrument face
  • Built-in 30A relay for direct heater switching, or a solid state relay drive for an external module
  • ±1°C accuracy across 0–400°C
  • DC 6–36V input for a two-wire proximity switch
  • A second input pair starts the timer from a pushbutton or a proximity switch
  • Setpoints and the counter value are held after power-off
  • 220VAC, 50/60Hz supply, CE marked

Works with

The parts that go into the same panel and are usually ordered with it.

Terminal layout and wiring

Thirteen terminals: 1–6 along the bottom edge and 7–13 down the right-hand side, numbered as they are moulded on the case. The two versions differ in one place only — the heating path across 3 and 4 — so both are drawn out below rather than folded into one drawing with a note.

1N2L3Heat4Heat5Valve6Valve7E-stop8E-stop9Trigger10Trigger11—12TC −13TC +SupplyHeatingValveE-stopTimerSpareThermocouple
Terminal reference, 1–13. Terminal 11 is not used.

TS800-30A

Built-in relay — the heater switches inside the case

TS800LCD touch · temperature · timer · counterHEAT16°C005SCOUNTER00005☰▼▲◉1234561312111098711 — not usedK thermocouple13 (+) · 12 (−)Timer pushbutton9–10 · or a proximity switchEmergency stop7–8 · normally closedHeaterup to 1500WSolenoid valvefoil drop / die liftL220VAC 50/60HzNsupply rails2–32–546
  • Live
  • Neutral
  • Signal / control
Relay version: the heater hangs off terminal 4, the solenoid valve off terminal 6, and both return to neutral. The emergency stop and the timer trigger sit on the right-hand terminals.
  1. 1Neutral to 1, live to 2. Both are 220VAC; blue on 1 and red on 2.
  2. 2Fit both jumpers, 2–3 and 2–5. They are wires you add, not links inside the case: 2–3 gives the heating relay its live feed and 2–5 gives the valve contact its own.
  3. 3Heater between 4 and neutral. Terminal 3 is the relay common, so 4 closes to live and the heater sees the full supply.
  4. 4Solenoid valve between 6 and neutral. Terminals 5–6 close together with the heating output, which is what a hot-stamping head needs: the valve that drops the foil fires with the die.
  5. 5Emergency-stop switch on 7 and 8 — a normally-closed mushroom head, mounted on the machine and not on the instrument. Opening it drops the heating output.
  6. 6Timer trigger on 9 and 10 — a pushbutton, or the machine's proximity switch. K thermocouple on 13 (+) and 12 (−). Terminal 11 stays empty.

TS800-SSR

External solid state relay — the load current stays outside

TS800LCD touch · temperature · timer · counterHEAT16°C005SCOUNTER00005☰▼▲◉1234561312111098711 — not usedK thermocouple13 (+) · 12 (−)Timer pushbutton9–10 · or a proximity switchEmergency stop7–8 · normally closedHeaterup to 1500WSolenoid valvefoil drop / die liftL220VAC 50/60HzNsupply rails2–53 → +4 → −SSR3–32VDC control+−A1A26
  • Live
  • Neutral
  • Signal / control
SSR version: 3 and 4 become a DC control pair for the relay module, live feeds the module's load terminal, and the heater is switched on the live side outside the controller.
  1. 1Neutral to 1, live to 2, and keep the 2–5 jumper so the valve contact still has a live feed. The 2–3 jumper comes off on this version.
  2. 2On this version 3 and 4 are a DC control output, not a contact: 3 is the positive and 4 the negative of the pair that drives the module. Getting the pair the wrong way round will not damage the module, but it will not switch either.
  3. 3Live goes to one load terminal of the module and the heater to the other, with the heater return to neutral. The switching current never enters the controller.
  4. 4Terminals 5–6, 7–8, 9–10 and 12–13 are wired exactly as on the relay version.
  5. 5Match the module to the load: the built-in relay is rated 30A and 1500W, so a heater above that — or one switched often — is the case for this build rather than the relay one.

What the terminals do on the machine

  • The emergency stop is an input, not a button on the front. Terminals 7 and 8 take a normally-closed mushroom head mounted where the operator can reach it — on the press frame, not on the instrument face — and the controller drops the heating output when that circuit opens.
  • The counter and the setpoints are held after power-off, so a machine that is switched off overnight comes back with the same die temperature, the same dwell and the same count.
  • Terminals 9 and 10 accept either a plain pushbutton or a DC two-wire proximity switch, so the same pair can start the timer from a foot pedal or from a part-present sensor on the press.

Supply & OEM

Available with your logoMOQ 10 units·Lead time on quotation·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

Which sensors can the TS800 read?

Thermocouple; K as standard, E available to order. Confirm the input code on the unit before ordering

What output options does the TS800 have?

Built-in 30A relay for direct heater switching, or a DC drive for an external solid state relay

What supply voltage does the TS800 need?

220VAC, 50/60Hz

How accurate is the TS800?

±1°C

What is the temperature range?

0–400°C

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.