Temperature Controllers
TED-2001, K thermocouple, 0–400 °C, 380 V
The 0–400 °C dial on a 380 V supply, K thermocouple.

- Output
- K thermocouple, 0–400 °C dial, 380 V
- Bezel
- pointer dial
- Panel cut-out
- per the case
Technical specifications
| Series | TED / TEA pointer temperature controller |
|---|---|
| Models | TED-2001 / TEA-2001 |
| Panel sizes | TED 72×72 mm, TEA 96×96 mm |
| Ranges | 300 °C or 400 °C on the TED, 400 °C on the TEA |
| Input | K or E thermocouple |
| Output | relay contact output |
| Control | on/off with a fixed 2 °C differential |
| Accuracy | ±2.5% FS |
| Supply | 220 VAC, 50/60 Hz, with a 380 VAC build on request |
| Operating environment | 0–50 °C, 30–85% RH, no corrosive gas |
Product overview
Part no. SE-TED-TEAindustry model TED-TEA
Also known as: TED-2001 · TEA-2001 · pointer-scale On/Off temperature controller
Two pointer instruments for ovens and griddles. The temperature is read on a moving-coil scale, the setpoint is a printed dial, and a relay switches the heater across a fixed differential. Nothing to program and nothing to misread in a dark cabinet.
Ordering code
TED-2001 K 0–400 °C 380 V
The 0–400 °C dial on a 380 V supply, K thermocouple.
| Order code | TED-2001 K 0–400 °C 380 V |
|---|---|
| Bezel (mm) | pointer dial |
| Cut-out (mm) | per the case |
| Output | K thermocouple, 0–400 °C dial, 380 V |
| Output terminals | per the case diagram |
| Input | Universal, K thermocouple fitted |
| Alarm | Two relays, A to L selectable |
| Supply | 220VAC 50/60Hz, 10VA |
What it can switch: The pointer closes a relay at the set point; nothing to configure beyond the dial
Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.
Other output stages of the same bezel
Key features
- TED-2001 / TEA-2001
- 300 °C or 400 °C on the TED, 400 °C on the TEA
- K or E thermocouple input
- relay contact output, on/off with a fixed 2 °C differential
- ±2.5% FS scale accuracy, 220 VAC, 50/60 Hz, with a 380 VAC build on request
Works with
The parts that go into the same panel and are usually ordered with it.
AC contactor
SE-CJX2
The 250 VAC / 3 A relay drives the coil; a contactor switches heaters above 750 W
K / E probe
SE-KPROBE
Factory-fixed K or E input, matched to the calibrated range of the ordered version
Pt100 / Cu50 RTD
SE-TC-WRNK236
Sheathed Pt100 or Cu50 probe for the fixed-range RTD versions, max 999 °C
Compatible sensors & outputs
also supplied as pointer-scale on/off temperature controller, analog dial panel thermostat
| Sensor | Range | Available as |
|---|---|---|
| K | Factory-fixed range, max 999 °C | K / E probe thermocoupleStainless steel probeSpring-loaded M12 probeRing-terminal thermocoupleThreaded shielded-lead probe |
| E | Factory-fixed range, max 999 °C | K / E probe thermocoupleStainless steel probeM6 / M8 screw-in probe |
| Pt100 | Factory-fixed range, max 999 °C | Pt100 / Cu50 sheathed RTDM6 / M8 screw-in probe |
| Cu50 | Factory-fixed range, max 999 °C | Pt100 / Cu50 sheathed RTD |
Output types and what goes with them
| Output | Rating | Order with it |
|---|---|---|
| Dry-contact relay | 250 VAC / 3 A (resistive load ≤ 750 W); drives an external contactor for larger heaters | CJX2 AC contactor |
Two bezels, no display
These are pointer instruments: the temperature is read off a scale, the setpoint is a printed dial, and no number is ever shown digit by digit. That is what makes them the cheapest thing in the panel and the easiest for an operator to set without a manual.
| Model | Panel W×H (mm) | Ranges |
|---|---|---|
| TED-2001 | 72 × 72 mm | 300 °C or 400 °C |
| TEA-2001 | 96 × 96 mm (1/4 DIN) | 400 °C |
What is ordered
Each model is built to one combination of range, thermocouple type and supply. The code on the label stays the same, so the three choices have to be named on the order line.
- Range300 °C or 400 °C on the TED; 400 °C on the TEA
- ThermocoupleK or E
- Supply220 VAC as standard, 380 VAC on request
Reading it on the machine
- The pointer shows the measured temperature; the setpoint is where the dial's own mark sits, and the two are separate — moving the knob does not move the pointer
- Two lamps: green on while the heater is being powered, red once the setpoint is reached
- The switching differential is a fixed two degrees, so the temperature holds in a band either side of the mark rather than sitting on it
- On a 300 degree version the scale runs to 300 and a 400 degree job needs the other version, not a re-set of the dial
Wiring
Ten terminals in two rows. The thermocouple lands on 1 and 2, the relay on 6 and 7 and 8, and the supply on 9 and 10. On this model the low side of the relay output is bridged to neutral, which is what makes it a single-pole switch rather than a floating contact.

| Terminal | Function |
|---|---|
| 1 · 2 | Thermocouple — red to 1, blue to 2 |
| 6 | Relay common (High side label) |
| 7 | Relay common terminal (Com) |
| 8 | Relay low, bridged to 9 |
| 9 | Neutral (N) |
| 10 | Live (L) |
220 V and 380 V versions wire the same way; only the transformer inside the case differs, so a 380 V unit drops into a panel wired for 220 V without changing the terminal plan.
Against the TEL pointer
Both are pointer controllers for ovens; the TEL96 is the larger 96 square body with the dial below the scale, while these two split into a 72 and a 96 with the scale above. Where a panel already has a 72 cut-out, the TED is the one that fits without opening it out.
| TED / TEA | TEL96 | |
|---|---|---|
| Bezels | 72 and 96 square | 96 square |
| Readout | pointer scale | pointer scale or LED on the 9001 |
| Ranges | 300 or 400 °C | 400 °C |
| Supply | 220 V or 380 V | 220 V or 380 V |
One page per order code
Every code this family ships, with the bezel, the output stage and the terminals that output uses.
TED-2001
pointer dialmm · cut-out per the casemm
Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 3 years
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Frequently asked questions
What panel size and cut-out does the TED-2001 need?
TED 72×72 mm, TEA 96×96 mm
Which sensors can the TED-2001 read?
K or E thermocouple
What output options does the TED-2001 have?
relay contact output
What supply voltage does the TED-2001 need?
220 VAC, 50/60 Hz, with a 380 VAC build on request
How accurate is the TED-2001?
±2.5% FS
What is the temperature range?
300 °C or 400 °C on the TED, 400 °C on the TEA
Related guides
TEL96-9001 or TEL96-2001: Choosing the Right Oven Temperature Controller
The TEL96 series is a 96 x 96 mm on/off oven temperature controller built around a K-type thermocouple input and a 10 A relay contact. It is made in two versions, the TEL96-9001…
Read guide Technical Guides · 2026-11-21Over-Temperature Protection and Interlock Wiring for Industrial Heating Equipment
A controller alarm tells an operator that something is wrong; it does not stop the heater. This guide shows how to add an independent limit controller, a normally-closed safety…
Read guide Technical Guides · 2026-08-27How to Wire CH102, CH402, CH702 and CH902 PID Temperature Controllers
A practical wiring guide for CH102, CH402, CH702 and CH902 PID temperature controllers, covering power, AC contactor and SSR control, thermocouple and Pt100 sensors, alarms and…
Read guideRelated models
All Temperature Controllers
TEL96-9001 Digital Dial Temperature Controller (96×96 mm, 0–400°C)
SE-TEL96-9001
The TEL96-9001 is a reliable, easy-to-operate ON/OFF temperature controller designed for commercial baking ovens, sealing machines, vacuum packaging…
View details
TCR Digital Dial Temperature Controller — TCR-M, 0–400°C, 100–240 VAC
SE-TCR
TCR Series Digital Dial Temperature Controller is a cost-effective temperature controller designed for simple and reliable heating control…
View details
TC7-D / TC7-R Dial Temperature Controller — thumbwheel or knob, 0–400°C
SE-TC7-D
75mm behind the bezel
View details
BT-72/96 BD & VD Dial Temperature Controller — thumbwheel or dial, 0–400°C
SE-BD-VD
108mm on the 72×72 and 125mm on the 96×96, behind the bezel
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.