Temperature Controllers

THF-2611, Timer and temperature, relay output

The THF-2611 build with timer and temperature, relay output.

THE-2000 temperature controller, K thermocouple, relay output, or solid state relay drive
THE-2000: K thermocouple; Relay output, or solid state relay drive; 0–999°C.
Output
Timer and temperature, relay output
Bezel
72 × 72
Panel cut-out
68 × 68
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesTHE-2000 / THF-2000 / THD-2000
ModelsTHE-2611, THE-2511, THF-2611, THF-2511, THD-2611, THD-2511
Case formsTHE vertical 48 × 96, THF horizontal 96 × 48, THD square 72 × 72mm
Panel cut-outsTHE 45 × 92, THF 92 × 45, THD 68 × 68mm
Depth75mm overall, 71mm behind the bezel
Supply85–265VAC, 50/60Hz
Measurement accuracy±1.0%FS
Control modePID control, or two-position on/off with adjustable differential
Input typeK thermocouple
Output typeRelay output, or solid state relay drive
Output rating250VAC 30A switching, 250VAC 5A on the time output
AlarmNo alarm relay; the second output is the timer
Temperature range0–999°C
Environment0–50°C, 30–85%RH, non-corrosive atmosphere

Product overview

Part no. SE-THE2000

Also known as: THE-2000 / THF-2000 temperature controller · THE-2000 / THF-2000 Temperature and Time Controller

One instrument for the two settings a heat press actually needs: platen temperature and dwell time. The temperature is held by PID to ±1.0%FS over 0–999°C; the timer counts down and closes its own 250VAC 5A output when the press has finished, so nobody stands over a stopwatch. The 85–265VAC, 50/60Hz supply covers 110 V and 230 V panels without a different part number, and the case comes in three forms — THE vertical 48 × 96, THF horizontal 96 × 48, THD square 72 × 72mm — with cut-outs of THE 45 × 92, THF 92 × 45, THD 68 × 68mm and a depth of 75mm overall, 71mm behind the bezel.

Ordering code

THF-2611, Timer and temperature, relay output

The THF-2611 build with timer and temperature, relay output.

Order codeTHF-2611, Timer and temperature, relay output
Bezel (mm)72 × 72
Cut-out (mm)68 × 68
OutputTimer and temperature, relay output
Output terminalsper the case diagram
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: Selected on the order line; the terminals follow the case diagram for that version

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Key features

  • Temperature and time in one instrument
  • ±1.0%FS accuracy over 0–999°C
  • PID control, or two-position with adjustable differential
  • 85–265VAC, 50/60Hz supply, so one part number covers 110 V and 230 V panels
  • 250VAC 30A switching on the 2611 versions; SSR drive on the 2511 versions
  • 250VAC 5A time output that closes when the countdown ends
  • K thermocouple input
  • No alarm relay — the second output is the timer, which is what a heat press panel needs
  • THE vertical 48 × 96, THF horizontal 96 × 48, THD square 72 × 72mm, cut-outs THE 45 × 92, THF 92 × 45, THD 68 × 68mm
  • 75mm overall, 71mm behind the bezel, so it drops into an existing panel depth
  • Environment 0–50°C, 30–85%RH, non-corrosive atmosphere

Works with

The parts that go into the same panel and are usually ordered with it.

Ordering & Selection Guide

Three letters name the case form (THE / THF / THD), then four digits set family (2), output (6 = relay, 5 = SSR), input (1 = K), and time output (1).

1THE-22364151

  1. 1

    Case form

    THE 48×96 · THF 96×48 · THD 72×72

  2. 2

    Family

    2 (fixed)

  3. 3

    Output

    6 relay · 5 SSR drive

  4. 4

    Input

    1 K thermocouple

  5. 5

    Time output

    1 one time output

Case form

THE
Vertical 48×96mm · cut-out 45×92
THF
Horizontal 96×48mm · cut-out 92×45
THD
Square 72×72mm · cut-out 68×68

Main output (digit 2)

6
Relay output, 250VAC 30A
5
SSR drive for external solid state relay

All six orderable builds

THE-2611Vertical 48×96 · Relay 30A
THE-2511Vertical 48×96 · SSR drive
THF-2611Horizontal 96×48 · Relay 30A
THF-2511Horizontal 96×48 · SSR drive
THD-2611Square 72×72 · Relay 30A
THD-2511Square 72×72 · SSR drive

Worked example

THF-2511 is the horizontal 96×48 mm case with the 12 VDC SSR drive on terminals 12 (+) and 13 (−), 0–999 °C on a K thermocouple.

Compatible sensors & outputs

also supplied as oven temperature and time controller, dual-display baking controller

SensorRangeAvailable as
K0–300 / 0–600 / 0–999 °C (by ordered version)K / E probe thermocoupleStainless steel probeThreaded shielded-lead probe

Output types and what goes with them

OutputRatingOrder with it
High-current relay (2611)250 VAC / 30 A switching on 2611 versions; drives an external contactor for larger banksCJX2 AC contactor
SSR drive (2511)12 VDC SSR drive output on 2511 versions for solid state relay switchingSSR-DA single phase 10–40 A

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

THE-2611

72 × 72mm · cut-out 68 × 68mm

THE-2511

72 × 72mm · cut-out 68 × 68mm

THF-2611

72 × 72mm · cut-out 68 × 68mm

THF-2511

72 × 72mm · cut-out 68 × 68mm

THD-2611

72 × 72mm · cut-out 68 × 68mm

THD-2511

72 × 72mm · cut-out 68 × 68mm

Wiring

Four panels: the relay versions driving a contactor or a heater directly, the SSR version driving a solid state relay, and the terminal reference for both. Terminal 9 feeds the output through a jumper on the relay versions; on the SSR version there is no jumper, because 12 and 13 become the 12 VDC drive.

THE / THF / THD-2000 series · wiring and terminal reference

THE / THF / THD-2000 series · wiring and terminal reference

Direct load limits on the 2611 versions: 1 500 W at 10 A and 4 500 W at 30 A. Above that the output closes a contactor, which is the first panel. Terminals 3 and 4 take a momentary switch — without it the countdown mode cannot be started by hand.

Download the sheet (PDF)

Documents for this family

All documents

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.