Temperature Controllers

96 Series Temperature Controller with Optional Timer

96×96mm temperature controller with an optional timer, a front-panel data lock, ±1°C accuracy and a 30A relay output for dryers and ovens.

96×96mm temperature controller with optional timer
96×96mm front, 92×92mm cutout, 58mm case depth
Panel size
96×96mm (1/4 DIN)
Panel cutout
92×92mm
Control output
Relay contact
Supply voltage
220VAC, 50/60Hz
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

Series96 Series (96mm square-bezel temperature controller, with or without timer)
Models0–300°C, 0–600°C and 0–999°C, each with or without the timer function
DisplayDigital LED, PV and SV
Control methodPID with auto-tuning, ON/OFF
InputK and E thermocouple
Temperature range0–300°C, 0–600°C or 0–999°C by model
Control outputRelay contact
Relay contact rating30A contact, 4500W resistive load
Parameter lockFront-panel data lock, so settings cannot be changed by operators
Supply voltage220VAC, 50/60Hz
Accuracy (listing)±1°C
Accuracy (supplier card)±0.5%FS
Power consumption<30VA
Insulation strength150VAC for 1 minute
Response time5s
Panel size96×96mm (1/4 DIN)
Panel thickness28mm bezel, 25mm into the panel
Panel cutout92×92mm
Dimensions (depth)58mm behind the bezel
Weight0.198kg
MountingPanel mount, flush bezel
CertificationCE

Product overview

Part no. SE-TC-96X96industry model TC-96X96

Also known as: 96×96mm 30A temperature controller · oven timer temperature switch

This 96×96mm (1/4 DIN) controller comes in six versions: 0–300°C, 0–600°C or 0–999°C, each with or without a timer. The front-panel data lock is the feature that matters on a production machine — once the setpoint is locked an operator cannot change it without the key sequence, so a shift change cannot shift the process. Output is a 30A relay, ±1°C accuracy, and the case is 58mm deep, which leaves room in a shallow enclosure.

Key features

  • Front-panel data lock so operators cannot change the setpoint
  • 0–300°C, 0–600°C or 0–999°C, each with or without a timer
  • 30A relay output
  • ±1°C accuracy
  • 96×96mm front, 92×92mm cutout
  • 58mm case depth
  • K and E thermocouple input
  • CE marked

Works with

The parts that go into the same panel and are usually ordered with it.

Panel breakdown

Front panel of the 96 Series controller: two three-digit display rows, three indicator lamps and four keys, each pointed at by a callout
Front-panel layout of the 96 Series. The silkscreen legends stay in English because they are what the unit itself carries.

Swipe the drawing sideways to see all of it.

  • PV

    Process value

    The upper row, three digits. This is the temperature the thermocouple is reading at this moment, not the target — on a cold start it climbs from ambient to the set point over the first minutes of the cycle.

  • SV

    Set value

    The lower row. Normally the target temperature; while a parameter is open it shows that parameter's value instead, which is why the legend calls it target or parameter.

  • °C

    Unit

    Printed once, beside the upper row. The specification states degrees Celsius only, so both rows read in the same unit and there is no unit switch to set.

  • OUT

    Output lamp

    Lit while the relay is closed and the element is being driven. Under PID the lamp pulses: the closer the process sits to the set point, the shorter the on time, so a steady glow means the loop is asking for full power.

  • ALM/TIME

    Alarm or timer lamp

    One lamp with two legends on it. These builds are specified with a single control relay and no alarm output, so the lamp is read as the timer lamp on the versions that carry the timer; the ALM half of the legend comes from the same moulding, not from a function this range lists.

  • AT

    Auto-tuning lamp

    Lit while PID auto-tuning is running. It goes out once the controller has derived its P, I and D values from the process it just watched, and starts controlling with them.

  • Set

    SET / Mode key

    Opens the parameter list and steps to the next parameter; on the last one it returns to the run display. The key is printed in the lighter colour because it is the one an operator presses first.

  • Shift/AT

    Shift and auto-tune key

    Moves the digit being edited, which is how a four-figure parameter is set without pressing the up key a hundred times. The AT half starts auto-tuning from the run display.

  • Dec/Rst

    Down and reset key

    Lowers the value. The second function is printed as Rst; the supplier's sheet does not spell out what it resets, so confirm it on the unit before a recipe depends on it.

  • Inc/BL

    Up and backlight key

    Raises the value. BL is printed as the second function; the specification lists no display backlight, so that half stays unconfirmed until the unit is in hand.

Front-panel data lock

The lock is set from the front panel itself. With it on, an operator cannot change the set point without the unlock sequence, so a change of shift does not change the process — which is what puts this controller on a production machine rather than on a test bench.

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

Compatible sensors & outputs

also supplied as 96×96 mm 30A oven temperature controller, digital temperature and timer switch

SensorRangeAvailable as
K0–300 / 0–600 / 0–999 °C (by ordered version)K / E probe thermocoupleStainless steel probeThreaded shielded-lead probe

Output types and what goes with them

OutputRatingOrder with it
High-current relay250 VAC / 30 A resistive contact; use an external contactor for heavy inductive or three-phase loadsCJX2 AC contactor

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

What panel size and cut-out does the 96 Series need?

96×96mm (1/4 DIN). The cut-out is 92×92mm

Which sensors can the 96 Series read?

K and E thermocouple

What output options does the 96 Series have?

Relay contact

What supply voltage does the 96 Series need?

220VAC, 50/60Hz

How accurate is the 96 Series?

±1°C

What is the temperature range?

0–300°C, 0–600°C or 0–999°C by model

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.