Thermocouples & RTD Sensors

Spring-loaded M12 sensor, Pt100 RTD, 1 m lead

The 1 m build of the pt100 rtd version.

Spring-loaded M12 thermocouple with an adjustable spring and braided lead
The spring keeps the tip against the surface as the platen expands.
Output
Pt100 RTD, 1 m lead
Bezel
probe
Panel cut-out
process thread
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

Product typeSpring-loaded M12 sensor that holds its tip against the part as the machine heats and expands
ElementK type (0–600°C), E type (0–400°C) or Pt100 RTD (−50 to +420°C) — state the element with the order
ToleranceClass 1 or Class 2 for K and E (IEC 60584); Class A or B for Pt100 (IEC 60751) — state it with the order
ThreadM12 × 1.5 standard; M8 × 1.0, M8 × 1.25, M10 × 1.0, M10 × 1.5, M12 × 1.0, M14 × 1.5, PT 1/8 and PT 1/4 to order
Body58mm from the tip to the end of the cap; the Ø5 probe tip is 30mm long, of which the first 16mm is plain
Reach (L)Set by the spring travel, not by a fixed length — say how deep the tip has to reach
Lead length1m / 1.5m / 2m / 3m; other lengths to order
Lead insulationMetal braid is the default; a yarn-wrapped glass-fibre lead is available to order
Cable constructionSilver-plated conductor on a glass-fibre core under a metal braid; a yarn-wrapped glass-fibre jacket is the other option — state which when ordering
TerminationU-type fork terminals
MountingThreaded into a tapped hole, with the spring taking up the depth
Typical useInjection moulding machines, moulds, hot runners and plastic machinery where the body grows as it heats
WiringTwo-wire for K and E — the red fork is + and the blue is − — and three-wire for Pt100. Confirm the colour code on the lead before wiring.

Product overview

Part no. SE-TC-M12industry model TC-M12

Also known as: Spring-Loaded M12 K/E temperature sensor · Spring-Loaded M12 K/E probe

A spring-loaded M12 sensor. The thread fixes it in the hole and the spring takes up the difference as the body heats and grows, so the tip stays against the part instead of backing off it. K, E or Pt100 element, on a lead in metal braid or fibreglass.

Ordering code

Pt100 · 1 m

The 1 m build of the pt100 rtd version.

Order codePt100 · 1 m
Bezel (mm)probe
Cut-out (mm)process thread
OutputPt100 RTD, 1 m lead
Output terminalsfork or pin terminals
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: The lead length is what the panel distance decides; the element is what the instrument reads

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Reading this order code

How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.

PositionReadsMeaning
elementPt100Sensing element inside the probe
lead1 mLead length to the panel; 1 m to 5 m are stock lengths
option—Other lengths, diameters and threads to order
Output terminals: fork or pin terminals·The lead length is what the panel distance decides; the element is what the instrument reads

Key features

  • The spring, not the thread, sets the reach — say how deep the tip has to go, not just the thread size.
  • M12 × 1.5 standard, with M8, M10, M14, PT1/8 and PT1/4 to order, and an extended M12 thread for thick walls.
  • Metal braid or fibreglass lead, in 1m, 1.5m, 2m or 3m.
  • K, E or Pt100 element in the same housing, so one spare fits every machine on the line.
  • U-type fork terminals land straight on the controller's screw terminals with no preparation.

Works with

The parts that go into the same panel and are usually ordered with it.

Thermocouple index and ranges

Eight letter codes cover almost everything on a panel. The letter is the alloy pair, and the range beside it is what the pair can be trusted to measure — outside that range the millivolt curve stops being usable, whatever the controller claims.

TypeAlloysWorking rangeWhere it is used
KNiCr–NiSi−200…1300 °CThe default. Ovens, extruders, heat presses, kilns below 1200 °C
ENiCr–CuNi−200…800 °CHighest EMF per degree, so the noisiest installations still read
JFe–CuNi−40…750 °COlder plant and reducing atmospheres; iron oxidises if it gets wet
NNiCrSi–NiSi−200…1300 °CWhere K drifts: long holds, cycling furnaces, sulphur-bearing gas
TCu–CuNi−200…350 °CLow temperature and cryogenic work, chillers, food equipment
SPt10Rh–Pt0…1600 °CKilns and glass; needs a thin sheath and clean air
RPt13Rh–Pt0…1600 °CSame duty as S with a higher output; platinum and ceramic firing
BPt30Rh–Pt6Rh600…1700 °CVery high temperature only: glass melt, refractory, 1500 °C and above

Ranges are the industrial working range, not the full IEC 60584 table. Type B has almost no output below 600 °C, which is why it is never specified for a low-temperature job.

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

How to specify

Four choices: element, thread, lead length and lead construction. SL-K-12-100-B is a K type element on an M12 × 1.5 thread, 1 m of metal-braided lead.

SLFamily
KElement
12Thread
100Lead, cm
BLead version

Fixed in this familyChosen when ordering

PositionCodeSelects
FamilySLSpring-loaded sensor
ElementKK type thermocouple
EE type thermocouple
PPt100 RTD
Thread12M12 × 1.5, standard
08M8 × 1.25
10M10 × 1.0
14M14 × 1.5
G2PT 1/8
G4PT 1/4
Lead, cm1001 m lead
2002 m lead
3003 m lead
5005 m lead
Lead versionBMetal braid over the lead
FFibreglass insulation
  • The spring, not the thread, sets how far the tip reaches: the thread fixes the sensor in the hole and the spring takes up the difference as the machine heats and expands. State the reach you need, not just the thread.
  • Extended M12 threads are available for thick walls; say the wall thickness when ordering.

Dimensions

L, the thread and the lead length are the three dimensions that have to be settled before a probe can be designed into a machine. Everything else on these sensors is fixed by the family.

L — tip reach, spring compressedM12 × 1.5Spring travel1 / 2 / 3 / 5 m

Six design points

  • Premium materials — the body, the thread and the spring are selected for the hot zone the probe works in.
  • Low-temperature start — the Pt100 version reads from −50°C, so one sensor covers the cold and hot ends of a process.
  • Abrasion resistance — the braided lead and the machined thread take repeated fitting and handling.
  • Layered inspection — each batch is checked at more than one stage before it is packed.
  • Years of development — the design has been refined over years of production rather than issued as a new pattern.
  • Quality assurance — every sensor is tested before it is dispatched.

Thread heads

M12 × 1.5 is fitted as standard. Every other head is machined to order, and where the wall is thicker than a standard thread is long, quote the wall thickness and an extended thread is supplied.

  • M8 × 1.0
  • M8 × 1.25
  • M10 × 1.0
  • M10 × 1.5
  • M12 × 1.0
  • M12 × 1.5 (standard)
  • M14 × 1.5
  • PT 1/8
  • PT 1/4
  • Extended M12 × 1.5

Product photos

Spring-loaded M12 thermocouples with metal-braided and fibreglass leads
The same sensor on a metal-braided lead and on a yarn-wrapped fibreglass lead.
Spring-loaded M12 thermocouple coiled with its U-type fork terminals
Coiled for packing: the spring, the M12 compression fitting and the U-type forks.
Three spring-loaded M12 thermocouples laid side by side
K, E and Pt100 elements share one body, so one spare fits every machine on the line.

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
12 months
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Frequently asked questions

How do I work out the reach I need?

Measure from the face of the tapped hole to the point you want to measure, with the machine cold, then add the growth you expect at working temperature. The thread fixes the sensor in the hole and the spring covers the difference, so the reach is the number to quote — the thread on its own does not fix it.

Metal braid or fibreglass lead?

Braid where the lead is handled, dragged across a machine or run beside contactors and drives: it protects the conductors and shields the signal. Fibreglass where the lead sits in a hot zone and nothing rubs against it, because there is no braid to fray.

Will it fit the hole I already have?

M12 × 1.5 is standard. M8, M10, M14, PT 1/8 and PT 1/4 are produced to order, and an extended M12 thread is available where the wall is thicker than the standard thread is long — quote the wall thickness when you order.

Can I use it on a Pt100 controller?

Yes — order the Pt100 element. It is wired three-lead, so the controller has to have three-wire RTD compensation, and the lead length becomes part of the measurement rather than something the controller ignores.

Certification and model-specific options

Certification

If CE or RoHS documentation is required, identify the exact model and ask us to confirm which current documents apply with the quotation. ATEX / IECEx zone-rated assemblies are not listed in this range; confirm requirements before specifying.

OEM and private label

Private-label marking or packaging may be available for selected probe models. The marking locations, supported construction and minimum quantity are confirmed against the model and order in the quotation.

What can be changed

Thread, sheath, lead insulation, terminal style and insertion length depend on the probe model and construction. Send the drawing or installation dimensions and we will confirm available options and quote accordingly.

Tolerance has to be stated

A tolerance class is not implied by a part number. Say Class 1 or Class 2 for K and E type (IEC 60584), Class A or B for Pt100 (IEC 60751), on the order — otherwise the probe is built to the standard class and the loop may not hold the accuracy you designed for.

Pressure

None of these probes is rated for pressure service. If the sensor goes into a pressurised pipe or vessel, ask for a thermowell and we will supply a probe that fits it — a bare sheath in a pressurised line is a leak waiting to happen.

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.