Thermocouples & RTD Sensors
Spring-loaded M12 sensor, Pt100 RTD, 2 m lead
The 2 m build of the pt100 rtd version.

- Output
- Pt100 RTD, 2 m lead
- Bezel
- probe
- Panel cut-out
- process thread
Technical specifications
| Product type | Spring-loaded M12 sensor that holds its tip against the part as the machine heats and expands |
|---|---|
| Element | K type (0–600°C), E type (0–400°C) or Pt100 RTD (−50 to +420°C) — state the element with the order |
| Tolerance | Class 1 or Class 2 for K and E (IEC 60584); Class A or B for Pt100 (IEC 60751) — state it with the order |
| Thread | M12 × 1.5 standard; M8 × 1.0, M8 × 1.25, M10 × 1.0, M10 × 1.5, M12 × 1.0, M14 × 1.5, PT 1/8 and PT 1/4 to order |
| Body | 58mm from the tip to the end of the cap; the Ø5 probe tip is 30mm long, of which the first 16mm is plain |
| Reach (L) | Set by the spring travel, not by a fixed length — say how deep the tip has to reach |
| Lead length | 1m / 1.5m / 2m / 3m; other lengths to order |
| Lead insulation | Metal braid is the default; a yarn-wrapped glass-fibre lead is available to order |
| Cable construction | Silver-plated conductor on a glass-fibre core under a metal braid; a yarn-wrapped glass-fibre jacket is the other option — state which when ordering |
| Termination | U-type fork terminals |
| Mounting | Threaded into a tapped hole, with the spring taking up the depth |
| Typical use | Injection moulding machines, moulds, hot runners and plastic machinery where the body grows as it heats |
| Wiring | Two-wire for K and E — the red fork is + and the blue is − — and three-wire for Pt100. Confirm the colour code on the lead before wiring. |
Product overview
Part no. SE-TC-M12industry model TC-M12
Also known as: Spring-Loaded M12 K/E temperature sensor · Spring-Loaded M12 K/E probe
A spring-loaded M12 sensor. The thread fixes it in the hole and the spring takes up the difference as the body heats and grows, so the tip stays against the part instead of backing off it. K, E or Pt100 element, on a lead in metal braid or fibreglass.
Ordering code
Pt100 · 2 m
The 2 m build of the pt100 rtd version.
| Order code | Pt100 · 2 m |
|---|---|
| Bezel (mm) | probe |
| Cut-out (mm) | process thread |
| Output | Pt100 RTD, 2 m lead |
| Output terminals | fork or pin terminals |
| Input | Universal, K thermocouple fitted |
| Alarm | Two relays, A to L selectable |
| Supply | 220VAC 50/60Hz, 10VA |
What it can switch: The lead length is what the panel distance decides; the element is what the instrument reads
Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.
Other output stages of the same bezel
Reading this order code
How the code on this page is put together, part by part — the same breakdown the series page gives, filled in for this version.
| Position | Reads | Meaning |
|---|---|---|
| element | Pt100 | Sensing element inside the probe |
| lead | 2 m | Lead length to the panel; 1 m to 5 m are stock lengths |
| option | — | Other lengths, diameters and threads to order |
Key features
- The spring, not the thread, sets the reach — say how deep the tip has to go, not just the thread size.
- M12 × 1.5 standard, with M8, M10, M14, PT1/8 and PT1/4 to order, and an extended M12 thread for thick walls.
- Metal braid or fibreglass lead, in 1m, 1.5m, 2m or 3m.
- K, E or Pt100 element in the same housing, so one spare fits every machine on the line.
- U-type fork terminals land straight on the controller's screw terminals with no preparation.
Works with
The parts that go into the same panel and are usually ordered with it.
Thermocouple index and ranges
Eight letter codes cover almost everything on a panel. The letter is the alloy pair, and the range beside it is what the pair can be trusted to measure — outside that range the millivolt curve stops being usable, whatever the controller claims.
| Type | Alloys | Working range | Where it is used |
|---|---|---|---|
| K | NiCr–NiSi | −200…1300 °C | The default. Ovens, extruders, heat presses, kilns below 1200 °C |
| E | NiCr–CuNi | −200…800 °C | Highest EMF per degree, so the noisiest installations still read |
| J | Fe–CuNi | −40…750 °C | Older plant and reducing atmospheres; iron oxidises if it gets wet |
| N | NiCrSi–NiSi | −200…1300 °C | Where K drifts: long holds, cycling furnaces, sulphur-bearing gas |
| T | Cu–CuNi | −200…350 °C | Low temperature and cryogenic work, chillers, food equipment |
| S | Pt10Rh–Pt | 0…1600 °C | Kilns and glass; needs a thin sheath and clean air |
| R | Pt13Rh–Pt | 0…1600 °C | Same duty as S with a higher output; platinum and ceramic firing |
| B | Pt30Rh–Pt6Rh | 600…1700 °C | Very high temperature only: glass melt, refractory, 1500 °C and above |
Ranges are the industrial working range, not the full IEC 60584 table. Type B has almost no output below 600 °C, which is why it is never specified for a low-temperature job.
One page per order code
Every code this family ships, with the bezel, the output stage and the terminals that output uses.
K
probemm · cut-out process threadmm
Pt100
probemm · cut-out process threadmm
How to specify
Four choices: element, thread, lead length and lead construction. SL-K-12-100-B is a K type element on an M12 × 1.5 thread, 1 m of metal-braided lead.
Fixed in this familyChosen when ordering
| Position | Code | Selects |
|---|---|---|
| Family | SL | Spring-loaded sensor |
| Element | K | K type thermocouple |
| E | E type thermocouple | |
| P | Pt100 RTD | |
| Thread | 12 | M12 × 1.5, standard |
| 08 | M8 × 1.25 | |
| 10 | M10 × 1.0 | |
| 14 | M14 × 1.5 | |
| G2 | PT 1/8 | |
| G4 | PT 1/4 | |
| Lead, cm | 100 | 1 m lead |
| 200 | 2 m lead | |
| 300 | 3 m lead | |
| 500 | 5 m lead | |
| Lead version | B | Metal braid over the lead |
| F | Fibreglass insulation |
- The spring, not the thread, sets how far the tip reaches: the thread fixes the sensor in the hole and the spring takes up the difference as the machine heats and expands. State the reach you need, not just the thread.
- Extended M12 threads are available for thick walls; say the wall thickness when ordering.
Dimensions
L, the thread and the lead length are the three dimensions that have to be settled before a probe can be designed into a machine. Everything else on these sensors is fixed by the family.
Six design points
- Premium materials — the body, the thread and the spring are selected for the hot zone the probe works in.
- Low-temperature start — the Pt100 version reads from −50°C, so one sensor covers the cold and hot ends of a process.
- Abrasion resistance — the braided lead and the machined thread take repeated fitting and handling.
- Layered inspection — each batch is checked at more than one stage before it is packed.
- Years of development — the design has been refined over years of production rather than issued as a new pattern.
- Quality assurance — every sensor is tested before it is dispatched.
Thread heads
M12 × 1.5 is fitted as standard. Every other head is machined to order, and where the wall is thicker than a standard thread is long, quote the wall thickness and an extended thread is supplied.
- M8 × 1.0
- M8 × 1.25
- M10 × 1.0
- M10 × 1.5
- M12 × 1.0
- M12 × 1.5 (standard)
- M14 × 1.5
- PT 1/8
- PT 1/4
- Extended M12 × 1.5
Product photos



Supply & OEM
- Stock / sample dispatch
- Typically 3–5 working days for available stock models after stock and order confirmation
- Warranty
- 12 months
- OEM
- Selected models; confirm by quotation
- Shipping
- Worldwide export
Frequently asked questions
How do I work out the reach I need?
Measure from the face of the tapped hole to the point you want to measure, with the machine cold, then add the growth you expect at working temperature. The thread fixes the sensor in the hole and the spring covers the difference, so the reach is the number to quote — the thread on its own does not fix it.
Metal braid or fibreglass lead?
Braid where the lead is handled, dragged across a machine or run beside contactors and drives: it protects the conductors and shields the signal. Fibreglass where the lead sits in a hot zone and nothing rubs against it, because there is no braid to fray.
Will it fit the hole I already have?
M12 × 1.5 is standard. M8, M10, M14, PT 1/8 and PT 1/4 are produced to order, and an extended M12 thread is available where the wall is thicker than the standard thread is long — quote the wall thickness when you order.
Can I use it on a Pt100 controller?
Yes — order the Pt100 element. It is wired three-lead, so the controller has to have three-wire RTD compensation, and the lead length becomes part of the measurement rather than something the controller ignores.
Certification and model-specific options
Certification
If CE or RoHS documentation is required, identify the exact model and ask us to confirm which current documents apply with the quotation. ATEX / IECEx zone-rated assemblies are not listed in this range; confirm requirements before specifying.
OEM and private label
Private-label marking or packaging may be available for selected probe models. The marking locations, supported construction and minimum quantity are confirmed against the model and order in the quotation.
What can be changed
Thread, sheath, lead insulation, terminal style and insertion length depend on the probe model and construction. Send the drawing or installation dimensions and we will confirm available options and quote accordingly.
Tolerance has to be stated
A tolerance class is not implied by a part number. Say Class 1 or Class 2 for K and E type (IEC 60584), Class A or B for Pt100 (IEC 60751), on the order — otherwise the probe is built to the standard class and the loop may not hold the accuracy you designed for.
Pressure
None of these probes is rated for pressure service. If the sensor goes into a pressurised pipe or vessel, ask for a thermowell and we will supply a probe that fits it — a bare sheath in a pressurised line is a leak waiting to happen.
Related guides
How to Wire CH102, CH402, CH702 and CH902 PID Temperature Controllers
A practical wiring guide for CH102, CH402, CH702 and CH902 PID temperature controllers, covering power, AC contactor and SSR control, thermocouple and Pt100 sensors, alarms and…
Read guide Technical Guides · 2026-08-25TEL96-9001 Temperature Controller Wiring Guide: Direct Heater and AC Contactor Methods
Terminal-by-terminal wiring for the TEL96-9001 ON/OFF temperature controller: K-type thermocouple connection, direct heater switching up to 1500 W, AC contactor control, 220 VAC…
Read guide Technical Guides · 2026-08-24How to Choose a Threaded Temperature Sensor: K, E Thermocouple or Pt100 RTD
A selection and installation guide for M6 / M8 threaded temperature sensor probes: how thermocouples and RTDs differ, which element to specify, how thread size and mounting affect…
Read guideRelated models
All Thermocouples & RTD Sensors
K/E Type Probe Thermocouple Temperature Sensor
SE-TC-KE
A Ø5mm probe in a spring housing. The thread section fixes it to a bracket or a tapped hole, and the spring keeps the tip pressed against the part,…
View details
Simple-Type Thermocouple or RTD | 4 × 40mm Probe, Clamp Mount, K / E / Pt100 / Cu50
SE-TC-4X40
The plainest sensor in the range: a 4 × 40 mm stainless probe on a braided lead, clamped against the part instead of screwed into it. Bolt the clamp…
View details
Sheathed Thermocouple or Pt100 RTD | Cast Aluminium Head, G1/2, 6mm Sheath
SE-TC-WRNK236
One mechanical version, two elements. The WRNK-236 takes a K type thermocouple for readings up to 0–800 °C; the WZP-236 takes a Pt100 for the colder…
View details
NTC Thermistor Temperature Sensor Probe | Stainless, Waterproof, Custom Lead
SE-NTC-PROBE
An NTC thermistor reads resistance rather than microvolts, so the same probe that suits a controller also suits a $5 thermostat: the resistance…
View detailsNeed help selecting the right model?
Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.