Temperature Controllers

XMTG-8511, K thermocouple, SSR output

The XMTG-8511 build with k thermocouple, ssr output.

XMT-8411 series PID temperature controllers in four bezels
XMTA, XMTD, XMTE and XMTG in the 8000 series: the same shell, a wider instrument.
Output
K thermocouple, SSR output
Bezel
96 × 96
Panel cut-out
92 × 92
Looking for a replacement? Compatibility depends on the exact model. Send your current part code or a nameplate photo and we’ll compare the panel cut-out, wiring, sensor input and output before you order. Request a cross-reference match

Technical specifications

SeriesXMT-8000 series panel PID temperature controller
ModelsXMTG-8411 / XMTE-8411 / XMTD-8411 / XMTA-8411
Panel sizes48×48×65, 48×96×65, 72×72×65 and 96×96×65 mm
Panel cutouts45×45, 45×92, 68×68 and 92×92 mm
Supply100–240 VAC, 50/60 Hz
Accuracy±0.5% or ±1.0% FS
ControlPID with autotuning, and on/off with an adjustable differential
Inputselectable input for K, E, J, S, R, B, N or T thermocouples, or Pt100 or Cu50 RTDs
Outputrelay contact 3 A at 250 V AC (resistive load), SSR drive, combined relay and SSR, or 4–20 mA
Alarmfull-range setting, up to two relays
Terminals24 and 23 supply; 22 output common with 21 and 20 as the SSR drive pair or the relay NO/NC; 19 and 18 alarm 1 NO/NC with 17 alarm 1 common and 16 alarm 2; 15, 14 and 13 the sensor — A/B/B for a 3-wire RTD, plus and minus for a thermocouple
Operating environment0–50 °C, 30–85% RH, no corrosive gas

Product overview

Part no. SE-XMT-8411industry model XMT-8411

Also known as: XMT-8411 temperature controller · XMT-8411 PID controller

The codes on this page carry an XMTG, XMTE, XMTD or XMTA front-panel prefix — XMTD-8411 included. XMTD-2001 and XMTD-2201 are a separate thumbwheel controller with a relay output, covered on their own page. See the XMTD-2001 / 2201 instead

The 8000 series is the smaller series' body with a wider instrument behind the bezel: one input that takes the whole thermocouple and RTD range, a second alarm relay, a current output, and half a percent accuracy on request. Four bezels, the same 65 mm behind the panel.

Ordering code

XMTG-8511, K thermocouple, SSR output

The XMTG-8511 build with k thermocouple, ssr output.

Order codeXMTG-8511, K thermocouple, SSR output
Bezel (mm)96 × 96
Cut-out (mm)92 × 92
OutputK thermocouple, SSR output
Output terminalsper the case diagram
InputUniversal, K thermocouple fitted
AlarmTwo relays, A to L selectable
Supply220VAC 50/60Hz, 10VA

What it can switch: Selected on the order line; the terminals follow the case diagram for that version

Terminals follow the diagram printed on the side of the instrument; if the unit you receive carries a different numbering, that diagram takes precedence.

Key features

  • XMTG-8411 / XMTE-8411 / XMTD-8411 / XMTA-8411
  • Panel cutouts 45×45, 45×92, 68×68 and 92×92 mm
  • selectable input for K, E, J, S, R, B, N or T thermocouples, or Pt100 or Cu50 RTDs
  • relay contact 3 A at 250 V AC (resistive load), SSR drive, combined relay and SSR, or 4–20 mA
  • ±0.5% or ±1.0% FS accuracy, 100–240 VAC, 50/60 Hz supply

Works with

The parts that go into the same panel and are usually ordered with it.

Four bezels, one body

Same shell and the same 65 mm behind the panel as the 6000 series; the difference is inside, where the input accepts ten sensor types instead of one family.

ModelPanel W×H×D (mm)Cutout (mm)
XMTA96 × 96 × 65 mm (1/4 DIN front)92 × 92
XMTD72 × 72 × 65 mm68 × 68
XMTE48 × 96 × 65 mm (1/8 DIN front)45 × 92
XMTG48 × 48 × 65 mm (1/16 DIN front)45 × 45

Ordering & Selection Guide

The 8000 series keeps the 6000 layout and widens two positions: the output gains a current version and, on the larger bezels, a combined relay-plus-SSR version; the alarm position carries a second relay.

XMTG①84②1③1④

① · Bezel letter

G48 × 48 × 65, cut-out 45 × 45
E48 × 96 × 65, cut-out 45 × 92
D72 × 72 × 65, cut-out 68 × 68
A96 × 96 × 65, cut-out 92 × 92

② · Main output

4Relay contact output
5SSR drive output
9Current output 4–20 mA

③ · Alarm output

1One alarm relay
3Two alarm relays

④ · Input type

1Thermocouple — K, E, J, S, R, B, N or T, set on the unit
2RTD — Pt100 or Cu50

Worked example

XMTG-8411

A controller with a 48 × 48 mm front, 8000 series, relay output, one alarm, thermocouple input. The same body with an SSR drive reads XMTG-8511, and with a Pt100 input XMTG-8412.

The codes that ship

Rather than a theoretical grid, these are the combinations the factory lists. Sizes below are the G; the same suffix works on E, D and A.

CodeVersion
XMTG-8411Relay output, one alarm, thermocouple
XMTG-8412Relay output, one alarm, Pt100
XMTG-8511SSR drive, one alarm, thermocouple
XMTG-8512SSR drive, one alarm, Pt100
XMTG-8431Relay output with two alarms
XMTG-8911Current output 4–20 mA
XMTE/D/A-8411The same versions on the larger bezels, where 8411 is a combined relay and SSR output

In the range

The 8411 is the step above the 6311: the same panel, a tighter display accuracy on request, a ten-type input, a second alarm and a current output. Where a machine only needs a K thermocouple and a relay, the 6311 does the job for less.

XMT 8411XMT 6311
Inputten types, selectablethermocouple or RTD
Accuracy±0.5% or ±1.0% FS±1.0% FS
Alarmsup to twoone as listed
Outputrelay, SSR, combined, or 4–20 mArelay or SSR

Compatible sensors & outputs

also supplied as XMT-8000 series controller, dual-output temperature controller

Show supported sensors & probe links (8: K, E, J, N, T, R / S / B, Pt100, Cu50)

Output types and what goes with them

OutputRatingOrder with it
Electromagnetic relay3 A at 250 VAC, resistive—
SSR drive, 12 VDCDrives a solid state relay; the module carries the loadSSR-DA single phase 10–40 A
Current output, 4–20 mAInto a controller or recorder input—
SCR / triac, zero-crossPhase-angle or zero-cross firingBDTY SCR voltage regulator

Input codes and measuring ranges

Most orders use K02 (K 0–400 °C), K06 (K 0–1200 °C), D10 (Pt100 0–500 °C) or 801 (4–20 mA). Expand the full table below for all 14 sensor types and range codes.

③ Full input code table (14 sensor types: K, J, R, S, B, E, N, T, Pt100, Cu50 & 4–20 mA)
InputCode and measuring range
KThermocouple
K01 0–200 °CK02 0–400 °CK03 0–600 °CK04 0–800 °CK05 0–1000 °CK06 0–1200 °CK07 0–1372 °CK13 0–100 °CK14 0–300 °C
JThermocouple
J01 0–200 °CJ02 0–400 °CJ03 0–600 °CJ04 0–800 °CJ05 0–100 °CJ06 0–1200 °C
RThermocouple (accuracy not guaranteed over 0–399 °C)
R01 0–1600 °CR02 0–1769 °CR03 0–1350 °C
SThermocouple (accuracy not guaranteed over 0–399 °C)
S01 0–1600 °CS02 0–1769 °C
BThermocouple (accuracy not guaranteed over 0–399 °C)
B01 400–1800 °CB02 0–1769 °C
EThermocouple
E01 0–800 °CE02 0–1000 °C
NThermocouple
N01 1–1300 °CN02 0–1300 °C
TThermocouple (accuracy held from −199 to 100 °C)
T01 −199.9–400.0 °CT02 −199.9–100.0 °CT03 −199.9–200.0 °CT04 0–350.0 °C
PT100RTD
D01 −199.9–649.0 °CD02 −199.9–200.0 °CD03 −100–50 °CD04 −100–100 °CD05 −100–200 °CD06 0.0–50.0 °CD07 0.0–100 °CD08 0.0–200 °CD09 0.0–300 °CD10 0.0–500 °C
Cu50RTD
P01 −50.0–150.0 °CP02 0.0–150.0 °CP03 0.0–100.0 °CP04 −50.0–0.0 °CP05 −50.0–100.0 °CP06 −50.0–50.0 °CP07 −50–150 °CP08 0–150 °CP09 0–100 °CP10 0–50 °C
0–5VDCStandard signal
401 0.0–100.0
1–5VDCStandard signal
601 0.0–100.0
0–20mAStandard signal, 250 Ω resistor across the terminals
701 0.0–100.0
4–20mAStandard signal, 250 Ω resistor across the terminals
801 0.0–100.0

Linear inputs scale over 0.0–100.0 in engineering units; 0–20 mA and 4–20 mA require a 250 Ω shunt resistor across the terminals.

Alarm type codes

The alarm position in the model code is a letter, not a number. These are the twelve codes the REX, CH and XMT families accept, in the order the factory sheets print them, so a code read off one sheet means the same thing on the next.

CodeAlarm type
NNo alarm
ADeviation high (upper)
BDeviation low (lower)
CDeviation high and low
DBand (deviation range)
EDeviation high, hold action
FDeviation low, hold action
GDeviation high and low, hold action
HProcess high (absolute)
JProcess low (absolute)
KProcess high, hold action
LProcess low, hold action

Codes E, F and G behave like A, B and C but stay latched after the condition clears, until the operator resets the instrument. K and L do the same for the absolute limits.

Codes H, J, K and L compare against an absolute temperature instead of an offset from the set point.

XMT-8000 series wiring

The XMT-8000 bodies carry a different block from the 8411 sheet above: it is numbered from 1, in ten or sixteen terminals. Six panels cover the XMTG-8411 and XMTG-8511 (ten terminals) and the XMTE-8411 and XMTA-8411 (sixteen), on a contactor, on a solid state relay and on an alarm light, with the terminal reference for each.

Read the block on your instrument before wiring: this sheet numbers it 1–10 or 1–16, while the drawing above this one numbers it 13–24. The same physical terminal is not the same number in both.

XMT-8000 series · six panels with terminal references

XMT-8000 series · six panels with terminal references

Download the sheet (PDF)

One page per order code

Every code this family ships, with the bezel, the output stage and the terminals that output uses.

XMTG-8411

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTG-8511

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTG-8412

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTG-8512

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTG-8431

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTG-8911

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTE-8411

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTE-8412

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTE-8431

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTE-8911

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTD-8411

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTD-8412

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTD-8431

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTD-8911

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTA-8411

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTA-8412

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTA-8431

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

XMTA-8911

96 × 96mm (1/4 DIN) · cut-out 92 × 92mm

Documents for this family

All documents

Supply & OEM

Available with your logoMOQ 500 pcs·10 days·OEM & private label →
Stock / sample dispatch
Typically 3–5 working days for available stock models after stock and order confirmation
Warranty
3 years
OEM
Selected models; confirm by quotation
Shipping
Worldwide export

Related guides

Need help selecting the right model?

Send us the load, voltage, sensor type and output signal. We reply with the matching model, wiring notes and an OEM quotation.